4.

 Control unit setting

4.1 -

 Dip-switch adjustment

DIP

SWITCHES

DIP

DIP-SWITCH

status

Description of

operation

DIP 1 STEP

DIP 2 AUTO

1-ON 2-OFF

Step-by-step command mode: 
Open / Stop / Close / Stop

1-ON 2-ON

Step-by-step with automatic 
closing (time set with the 
“Pause” knob)

1-OFF 2-ON

Opening only command 
mode with automatic closing 
(condominium function)

1-OFF 2-OFF

Open / Close / Open com-
mand mode (no Stop)

DIP 3 

CHECK

ON

Test of the safety devices 
connected at terminal [3] 
“Phototest” enabled

OFF

Test of the safety devices 
connected at terminal [3] 
“Phototest” disabled

DIP 4

FUNCTION

ON

Devices connected to “S2 
Photo” terminal [4] intervene 
just during closing phase with 
immediate inversion

OFF

Devices connected to “S2 
Photo” terminal [4] intervene 
by stopping the movement 
both in opening and closing 
phases

DIP1 “STEP”:

If the dip-switch is put to 

ON

, the step-by-step operating mode is 

activated. At every start pulse (wired or via transmitter), the control 
unit performs an action. Starts the motor if the automation system is 
stopped, and stops it if it is moving. If the “

STEP

” dip-switch is put 

to 

OFF

, the OPEN FULLY/PAUSE/CLOSE FULLY/STOP operating 

mode is activated (apartment block). The control unit only accepts 
commands (either wired or via transmitter) for the opening phase. 
Starts again from zero with the set delay when the automation sys- 
tem is open. With the automation in the opening phase, it continues 
to open, and with the system in the closing phase it reopens fully. 
The automation can re-close with the time set through the “

PAUSE

” 

knob, if the “

AUTO

” dip-switch is set to 

ON

. If not, it is necessary 

to give a START command (either wired or via transmitter) with the 
automation fully open.

DIP2 “AUTO”:

If the dip-switch is put to 

ON

, the automatic re-closing function is ac- 

tivated. The control unit automatically closes the leaves after the time 
set through the “

PAUSE

” knob (see Paragraph 4.2). If the “

AUTO

” 

dip-switch is put to 

OFF

, the automatic re-closing function is deac- 

tivated. To close the leaves, therefore, a command must be given 
(either wired or via transmitter).

DIP3 “CHECK”:

If the dip-switch is put to 

ON

, the safety devices connected to 

terminal “Phototest” [3] are subject to a preventive check before 
starting any movement. It's necessary to connect the positive 
terminal of photocell's transmitter (or the normally closed contact of 
a safety edge) to terminal n.3 in order to use this function.
If the “

CHECK

” dip-switch is put to 

OFF

, the safety devices 

connected to terminal “Phototest” [3] are constantly supplied.

DIP4 “FUNCTION”:

If the dip-switch is put to

 ON

, the safety devices connected to 

“S2 Photo” terminal [4] intervene just during closing phase with 
immediate inversion. If the dip-switch is put to 

OFF

, the safety 

devices connected to “S2 Photo” terminal [4] intervene by stopping 
the movement both in opening and closing phases.

4.2 -

 Knob adjustment

PAUSE

OBSTACLE

FORCE

 

KNOB

Description of

operation

FORCE

Power: adjustment of motor power. Turning the 
knob clockwise increases the motor’s power 
and speed. To validate the modification, it is 
necessary to programme the gate path.

OBSTACLE

Obstacle, sensitivity to obstacles: adjustment of 
the obstacle detection function. Turning the knob 
clockwise increases the drive time before obstacle 
detection (less sensitivity). Therefore, in systems with 
particularly unfavorable mechani- cal conditions, it is 
advisable to keep the drive time high. OBSTACLE is 
set at half position (50%) as factory setup.

PAUSE

Pause time before automatic gate closing. 
Turning the knob clockwise increases the pause 
time from 0 to 180 seconds. Please note: this 
knob is functional only when AUTO dip-switch is 
put to ON.

 

Varying the “POWER” knob has no effect until the stroke 

is reprogrammed (par. 6).

31

32

Содержание ELEVO

Страница 1: ...ELEVO EN Instructions and warnings for installation and use Made in Italy...

Страница 2: ......

Страница 3: ...ming of the button linkedto the on board courtesy light 13 5 4 Deleting all memorised transmitter 14 5 5 Deleting a single transmitter 14 5 6 Remote tools free transmitter programming 14 6 Programming...

Страница 4: ...KING gates Customer Service Do not make alterations to the product in any way Improper use can only lead to malfunctions The manufacturer declines all liability for damage caused by arbitrary modific...

Страница 5: ...ycles up to 2 16 8 2 2 4 12 6 Table 3 Limits in relation to force required to move door leaf Force required to move leaf N Cycle reduction percentage Up to 200 100 200 300 70 300 400 25 The height of...

Страница 6: ...or increasing the range of the transmitters Paragraph 10 8 Pause time for automatic re closing adjustable to between 0 and 180 sec with knob Paragraph 4 2 Obstacle sensitivity adjustment with knob Par...

Страница 7: ...and cause malfunc tions fire or dangerous situations If the door includes an access door make sure that it does not obstruct normal travel Fit a suitable interlock system if necessary Only insert the...

Страница 8: ...8 EN 6 1 2 3 4 4a 4b 4c 7 B 5 A 12 A 10 11 E E 9 B D 8 D C 13 F...

Страница 9: ...leaving the gearmotor on the ground lift the guide from the front section and secure using two screws plugs or rivets according to the installation surface 03 Secure the brackets H using the screws I...

Страница 10: ...he rear mechanical stop R next to the carriage fig 23 and tighten the screw Q fully down Important Make sure the release cord can be pulled below a height of 1 8 m 23 Q R 3 3 Installation of other dev...

Страница 11: ...t 1 1 2 3 4 5 6 7 8 9 10 11 12 2 3 4 ON DIP 13 14 Flash Aerial Phototest S2Photo 0 VDC STOP START 24VDC S1Edge 24VDC Lock Table 5 Terminals Function Description 1 2 Flash 24V max 15W warning light 3 P...

Страница 12: ...unction is ac tivated The control unit automatically closes the leaves after the time set through the PAUSE knob see Paragraph 4 2 If the AUTO dip switch is put to OFF the automatic re closing functio...

Страница 13: ...s 11 12 To use this function the Lock AUX output must be set to courtesy light see Paragraph 13 1 STEP ACTION RESULT 1 PRESS THE RADIO BUTTON FOR 1 SECOND The red radio LED turns on in the fixed mode...

Страница 14: ...ot consult Paragraph 14 1 2 PRESS THE SET BUTTON FOR 1 SECOND The red radio LED flashes and the yellow set LED turns on in fixed mode 3 PRESS A BUTTON ON THE TRANSMITTER YOU WISH TO CANCEL The red rad...

Страница 15: ...ding slowdown see paragraph 6 2 STEP ACTION RESULT 1 MOVE THE DOOR TO HALF WAY POSITION 2 PRESS THE SET BUTTON FOR 1 SECOND The yellow set LED flashes if not consult Paragraph 14 1 3 PRESS THE SET FOR...

Страница 16: ...TON OR A BUTTON OF A PAIRED TRANSMIT TER OR CLOSE START WIRED CONTACT TO SET THE SLOWDOWN START POINT FOR NOT HAVE SLOWDOWN WAIT UNTIL THE MOVEMENT HAS BEEN COMPLETED The yellow set LED stays on in th...

Страница 17: ...RED RADIO LED AND YELLOW SET LED If when attempting to enter any programming scheme the Set Radio and Error LEDs flash fast three times it means that the control unit protection is activated See Para...

Страница 18: ...active during closing and opening phase This input is normally closed NC For infra red photocells and safety edges with micro switch contact The factory wire bridge connected to S2 Photo must be remo...

Страница 19: ...agraph 4 1 This input is a voltage free dry contact only Connecting power to this input will void warranty TIMER FUNCTION if START contact is kept closed for in stance through a timer controlled or b...

Страница 20: ...el backjump value setting 5 EVERY TIME THE SET BUTTON IS PRESSED THE VALUE CHANGES FROM 1 TO 6 STARTING FROM THE CURRENTLY SET VALUE 1 5 2 4 3 6 example 1 current backjump 3 after SET is pressed backj...

Страница 21: ...t as electric lock see Paragraph 13 1 if desired program the transmitter button for the START com mand see Paragraph 5 1 At every wired or transmitter start command the light will switch on for the se...

Страница 22: ...THE SET AND RADIO BUTTONS SIMULTANEOUSLY OR WAIT 10 SECONDS TO EXIT THE PROCEDURE The LEDs return to the normal operation configuration To control the AUX contact set as courtesy light a radio command...

Страница 23: ...In order to carry out the check on the safety devices the connected edges must be of the resistive type with 8 2 kOhm 14 Other functions To interrupt the following programming sequences at any time pr...

Страница 24: ...ol unit stops powering the mo tor s at the end of the travel 3 If not sufficient turn the POWER knob slightly clock wise and reprogram automation s movement 4 Avoid reduce slowdown travel phase see Pa...

Страница 25: ...the dimensions stated in table 1 and limits specified in tables 2 and 3 ELEVO power supply 230Vac 10 50 60Hz Max absorbed power 200 W Insulation class 1 a safety grounding system is required Emergenc...

Страница 26: ...EC of the European Parliament and of the Council of 17 May 2006 on machinery and amending Directive 95 16 EC recast in accordance with the following harmonised standards It is hereby declared that the...

Страница 27: ......

Страница 28: ...cturer s details Timbro Stamp Azienda Company Localit Address Provincia Province Recapito telefonico Tel Referente Contact person King Gates S r l Phone 39 0434 737082 Fax 39 0434 786031 info king gat...

Отзывы: