![King gates ELEVO Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/king-gates/elevo/elevo_instructions-and-warnings-for-installation-and-use_1969526023.webp)
23
EN
13.4 -
Selection of the type of
devices connected to
“S1 Edge”
Default = “S1 Edge” set for devices with normally closed con-
tact (terminal 9)
This procedure allows for setting the “S1 Edge” output for managing
8.2kOhm resistive edges.
The control unit constantly verifies the integrity of the edge by meas-
uring the resistance between the two dedicated terminals.
STEP ACTION
RESULT
1
PRESS
START
BUTTON
FOR 3 SECONDS
All the LEDs turn off (if not,
consult Paragraph 14.1)
2
PRESS THE
START
BUTTON FOR 1 SECOND
2.1a
If the yellow “Set” LED is
on “S1 Edge” = resistive
edge (if the setting is
correct, go to Point 4; if
not, pro- ceed to Point 3a)
The red “
error
” LED turns
on in the fixed mode
3a
device with normally
closed (NC) contact
PRESS THE
START
BUTTON FOR 1 SECOND
The red “
error
” LED
remains lit in the fixed
mode and the yellow “
Set
”
LED turns off
or
2.1b
If the yellow “Set” LED is
off “S1 Edge” = device
with normally closed
(NC) con- tact (if the
setting is correct, go to
Point 4; if not, proceed
to Point 3b)
The red “
error
” LED turns
on in the fixed mode
3b
8.2 kOhm
resistive edge
PRESS THE
START
BUTTON FOR 1 SECOND
The red “
error
” LED
remains lit in the fixed
mode and the yellow “
Set
”
LED turns on
4
PRESS THE
SET
AND
RADIO
BUTTONS
SIMULTANEOUSLY OR
WAIT 10 SECONDS TO
EXIT THE PROCEDURE
The LEDs return to
the normal operation
configuration
In order to carry out the check on the safety devices, the
connected edges must be of the resistive type with 8.2 kOhm.
14.
Other functions
To interrupt the following programming sequences at any
time, press the SET and RADIO buttons simultaneously or
wait 10 seconds.
14.1 -
Activating/deactivating the
control unit protection device
Default = control unit protection device not active.
This programming sequence allows for locking all control unit pro-
gramming sequences and the settings adjustable through the
dip-switches. To perform a new programming sequence or make
a dip-switch/trimmer modification effective, the protection must be
deactivated.
STEP ACTION
RESULT
1
PRESS
START
BUTTON
FOR 3 SECONDS
All the LEDs turn off
2
PRESS THE
SET
BUTTON
FOR 1 SECOND
2.1a
If the yellow led “Set”, the
red led “Radio” and the red
led “Error” are ON: central
unit lock = enabled (if it is
the correct setting, go to
step 4, otherwise proceed
to step 3a)
3a
Enabling control unit setup
PRESS BOTH BUTTONS
START
AND
RADIO
, FOR
2 SECONDS
The yellow led “
set
”, the
red led “
radio
” and red led
“
start
” go OFF
or
2.1b
If the yellow led “Set”, the
red led “Radio” and red led
“Error” are OFF: central
unit lock = disabled (if it is
the correct setting, go to
step 4, otherwise proceed
to step 3b)
3b
Disabling control unit setup
PRESS BOTH BUTTONS
START
AND
RADIO
, FOR
2 SECONDS
The yellow led “
set
”, the
red led “
radio
” and red led
“
start
” go ON
4
PRESS BOTH BUTTONS
SET
AND
RADIO
SIMULTANEOUSLY OR
WAIT 10 SECONDS TO
EXIT THE PROCEDURE
All the LEDs go back to
standard behavior