Installation
February 2012
2-26
P/N 06-237058-001
2-7.5
Connecting Standby Batteries To PMU Board
Note:
Observe polarity when connecting batteries to the control unit.
To connect the standby batter(ies)to the control unit:
1. Calculate the size of the battery required for the application. Refer to Appendix A for the
proper procedure.
2. Connect two or more 12-volt, series-wired batteries of the required ampere-hour (AH)
capacity to Terminal J10 on the PMU Board using battery cables found in the PMU Board
hardware kit. See Figure 2-21 below.
Figure 2-21. Standby Battery Connections
WARNING
Batteries contain sulfuric acid that can cause severe burns to the skin and eyes and can
damage clothing. Immediately flush areas of the skin or eyes that have been contacted
with sulfuric acid for 15 minutes with water and seek medical attention promptly.
-
-
1
2
V
Ba
tter
y
1
2
V
Ba
tter
y
+
-
+
-
+
+
J
1
0
on
P
M
U
Ba
tter
y Cab
le
s
Ba
tter
y J
u
mp
er
-
-
1
2
V
Ba
tter
y
1
2
V
Ba
tter
y
+
-
+
-
+
+
J
1
0
on
P
M
U
Ba
tter
y Cab
le
s
Typ
ic
a
l
(by
in
s
t
a
ller
)
N
ote:
L
oc
a
te
a
ll
ba
tterie
s
in
a
co
mm
on
ba
tter
y
c
ab
inet or in clo
s
e-cou
p
led
ba
tter
y
c
ab
inet
s
wit
h a
ll
ba
tter
y
c
ab
le
s
in conduit.
Ba
tter
y J
u
mp
er
Typ
ic
a
l
(by
in
s
t
a
ller
)
1
2
V
Ba
tter
y
1
2
V
Ba
tter
y
+
-
+
-
S
ingle-
Ba
tter
y S
et In
s
t
a
ll
a
tion
D
u
a
l-
Ba
tter
y S
et In
s
t
a
ll
a
tion
Содержание ARIES NETLink
Страница 2: ......
Страница 14: ...Table of Contents February 2012 xii P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 20: ...List of Tables February 2012 xviii P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 78: ...Installation February 2012 2 22 P N 06 237058 001 Figure 2 17 Installing the Expansion Card Cage ...
Страница 112: ...Installation February 2012 2 56 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 166: ...Configuration and Programming February 2012 3 54 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 194: ...Operation February 2012 4 28 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 203: ...Networking P N 06 237058 001 5 9 February 2012 Figure 5 5 Processing Group 0 Networked Control Unit Interactions ...
Страница 222: ...Testing and Maintenance February 2012 6 4 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 250: ...Troubleshooting February 2012 7 28 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 268: ...List of Agency Listed Compatible Devices February 2012 C 4 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 270: ...FM Rules for Preaction Deluge Systems February 2012 D 2 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 286: ...ARIES NETLINK For City Of Chicago Applications February 2012 G 6 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 293: ......