Both NAC circuits are supervised, power limited, and are compatible with conventional, UL-Listed,
24-Vdc notification appliances such as:
•
MT Series Multi-Tone Horns and Horn/Strobes
•
NS Series Horn/Strobes
(See Note 1)
•
NH Series Horns
•
RSS(P) Series Strobes
(See Note 1)
•
Exceder Series
(See Note 1)
•
Commander Series
(See Note 2)
NOTE 1
: These strobes can be programmed for synchronization.
NOTE 2
: Commander Series strobes require the manufacturer’s synch module to synchronize
devices.
Horn/strobe combination devices utilizing the appropriate synch protocol have the option to use
silenceable horns and non-silenceable strobes. Refer to the horn/strobe manufacturer’s installation
sheet for details.
to estimate the maximum length of wire as a function of notification-appliance
current for NACs.
Figure 2-30. Wiring Length vs. Notification-Appliance Current
WARNING
All strobes are designed to flash with continuous applied voltage. Strobe notification
appliances cannot be used on pulsing signaling (NAC or R-NAC) circuits. You must use a
separate notification circuit if the application requires a pulsing signaling circuit for
horns. Failure to adhere to this warning may cause system malfunction.
0
500
1
000
1
500
2000
2500
3000
3500
4000
4500
5000
5500
6000
6500
7000
7500
8000
8500
9000
9500
1
0000
1
0500
11
000
11
500
1
2000
0
.1
0
.
2
0
.
3
0
.
4
0
.
5
0
.
6
0
.
7
0
.
8
0
.
9
1
1.1
1.
2
1.
3
1.
4
1.
5
NAC C
urrent
(A)
#1
8 A
WG
#1
6 A
WG
#1
4
A
WG
#1
2
A
WG
0
.
0
M
ax
i
m
u
m
NAC
W
ire
L
engt
h(
F
t.
)
Содержание ARIES NETLink
Страница 2: ......
Страница 14: ...Table of Contents February 2012 xii P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 20: ...List of Tables February 2012 xviii P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 78: ...Installation February 2012 2 22 P N 06 237058 001 Figure 2 17 Installing the Expansion Card Cage ...
Страница 112: ...Installation February 2012 2 56 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 166: ...Configuration and Programming February 2012 3 54 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 194: ...Operation February 2012 4 28 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 203: ...Networking P N 06 237058 001 5 9 February 2012 Figure 5 5 Processing Group 0 Networked Control Unit Interactions ...
Страница 222: ...Testing and Maintenance February 2012 6 4 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 250: ...Troubleshooting February 2012 7 28 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 268: ...List of Agency Listed Compatible Devices February 2012 C 4 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 270: ...FM Rules for Preaction Deluge Systems February 2012 D 2 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 286: ...ARIES NETLINK For City Of Chicago Applications February 2012 G 6 P N 06 237058 001 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 293: ......