background image

In this menu, you can choose between an Internal or External LoRa® Network Server.

4.1.5.2

LoRa® network server

Note

When submitting these settings, the ITG needs to be restarted.

Internal network server

When selecting "Internal Network Server", it is possible to check the MAC of the Gateway and 

enable / disable the following options: keep TX between reboots; maintain sensor reading between 
reboots; enable datalogger for LoRa; allow CRC with error or undefined.

22

Содержание ITG 200Indoor

Страница 1: ...User Manual ITG 200 Indoor...

Страница 2: ...end by interface 4 1 4 IEEE 802 15 4 network 4 1 4 1 IEEE 802 15 4 network hub 4 1 4 2 Update IEEE 802 15 4 devices 4 1 4 3 Map 4 1 5 LoRa 4 1 5 1 LoRa Radio 4 1 5 2 LoRa network server 4 1 5 3 Regist...

Страница 3: ...ocedure 7 2 IT release for the ITG 200 Gateway 7 2 1 MQTT send 7 2 2 HTTP send 7 2 3 External Network Server send 7 2 4 Connectivity Management 7 2 5 OpenVPN Khomp 7 2 6 Remote Update 7 2 7 PING test...

Страница 4: ...e through wired Ethernet connection or via 3G mobile network increasing your reliability in data delivery 2 1 Technical information Currently the ITG 200 operates with the following sensors Temperatur...

Страница 5: ...ector for auxiliary 3G antenna 2 Power supply connector 3 ETH0 RJ45 fast Ethernet port 4 ETH1 RJ45 fast Ethernet port 5 1 Wire port 1 6 1 Wire port 2 7 Reset button recovery mode 8 Wireless sensor ant...

Страница 6: ...menu It allows accessing the ITG 200 menu if it is in the initial interface Up arrow and down arrow Allows you to select the options available in the menu Left arrow Returns to the previous menu or t...

Страница 7: ...twork registration status AT CREG Network you are registered with AT COPS Registration status AT CGREG SIM card ICCID AT CCID 2 7 6 Enable DHCP This option allows the user to enable automatic obtainin...

Страница 8: ...200 if it is on 2 Remove the side screws from the cabinet Each side has a screw Slide towards the rear of the cab to remove it 3 Fit the module in its respective internal slot to the gateway as shown...

Страница 9: ...e two slots for the 3G modem are located inside the ITG 200 if the 3G network module is installed on the gateway 1 Turn off the ITG 200 if it is on 2 Remove the side screws from the cabinet Each side...

Страница 10: ...The arrows indicate the location where the spacers will be installed for the correct xing of the module Remove the existing screws and screw the spacers before tting the module The LoRa module similar...

Страница 11: ...n to the Web Interface The ITG 200 Web Interface displays a menu to the left of the interface with con guration options a panel for monitoring the sending of data collected by the sensors and diagnost...

Страница 12: ...he model version if available address and registration date of each device among other con guration options speci c to each device Note The ITG 200 itself will appear in the Device List as soon as it...

Страница 13: ...ce s downlink counter Reporting Period Field for editing the period of sending messages from the device to the gateway To IEEE 802 15 4 Zigbee devices Field Description Reporting Period Internal Allow...

Страница 14: ...le network DNS con guration and OpenVPN con guration Note Any deletion action once con rmed cannot be undone IEEE 802 15 4 devices will only be removed from the list when they con rm their exit from t...

Страница 15: ...should use MAC address It is the MAC address of the ITG 200 in case it is necessary to clone this address Con gure static IP address 1 Disable the Use DHCP option 2 Enter the IP address subnet mask an...

Страница 16: ...phone operator 2 Select the position in which the operator s SIM card is inserted that corresponds to APN 3 Restart the gateway for this information to take effect It is possible to register up to 4 A...

Страница 17: ...of the DNS server If you need to enter another DNS server click the Add new DNS button again and repeat the procedure 3 Click the Submit Con guration button 4 Restart the ITG 200 To con gure Openvpn...

Страница 18: ...update The connected Endpoints must be powered by USB and or new batteries Low battery endpoints can fail to update and corrupt your internal memory The update process takes time depending on the num...

Страница 19: ...s interaction is only visual and does not alter in any way the way in which the devices are really interconnected 4 1 4 3 Map The identi cation of the devices is carried out as follows Green Network c...

Страница 20: ...re displayed in Orange NITs in Blue and other devices in Lilac The Address network column is a unique identi cation associated with devices each time they enter the network that is if for any reason a...

Страница 21: ...also delimits the frequency values allowed by the chosen region Central Frequency Frequency in MHz used to con gure the LoRa Radio It is from it that the frequencies of the channels are calculated An...

Страница 22: ...ng these settings the ITG needs to be restarted Internal network server When selecting Internal Network Server it is possible to check the MAC of the Gateway and enable disable the following options k...

Страница 23: ...matically when entering the MAC EUI of the same if you have changed this address you will need to enter this information If the device keys are not Khomp standards or are using third party LoRa device...

Страница 24: ...ntered in the Message eld hexadecimal values must be entered Note The HTTP and MQTT protocols cannot be enabled used simultaneously All elds with are necessary to enable the respective protocols 4 1 6...

Страница 25: ...in this eld if any Scheme by SSL certi cate If the application server requires secure connection it is necessary to insert the SSL certi cate and the private key It is necessary to generate these les...

Страница 26: ...form the status of the mobile network since it will be used only a few times Message Reporting Period Period in seconds between sending messages to the server for each type of network Ethernet Time in...

Страница 27: ...s from the gateway IEEE 802 15 4 devices when available and the LoRa network server when available QoS Enter the desired QoS level MQTT User Enter the user name of the MQTT server MQTT Password Enter...

Страница 28: ...three elds are left empty the functionality will be automatically disabled so it is necessary to con gure at least one server to activate it The Update every eld when set to 0 zero causes the function...

Страница 29: ...hen clicking on Synchronize Date and Time with Computer the UTC Universal Time Coordinated time of the gateway will be updated based on the UTC time of the computer For viewing purposes on the Panel a...

Страница 30: ...etected If so it shows the number of devices connected and the time of the last message received if any Modem Displays whether the presence of the Modem has been detected If detected Modem status desc...

Страница 31: ...user as well as perform a TCP connection test over ethernet In this way it is possible to test the connectivity of the gateway to the internet in an advanced way checking if the server responds to pin...

Страница 32: ...r records found by the ITG 200 System logger It contains the startup information for the ITG 200 Heartbeats are also recorded every hour to indicate that the gateway is on OpenVPN logger Contains reco...

Страница 33: ...week and the time to automatically check for a new version available for update as shown in the gure below 4 The user noti cation panel which allows to activate deactivate the sending of an email not...

Страница 34: ...highlighted by a pink orange or blue panel and re ect an important action or the result of it In version 2 5 0 0 the following noti cations can be displayed 1 Gateway not registered on the Khomp Iot C...

Страница 35: ...ion popup available for update 7 Popup informing the need for a new login after updating 8 Noti cation e mail a Title New version available Gateway ITG 200 108290 b Content Hello A new version is avai...

Страница 36: ...egration protocol For information on the gateway integration protocol see the communication protocol manual available in our document area 36 6 Device registration guidelines For information on the ga...

Страница 37: ...device s reception windows open and the frequency of the second reception window and also which is the MAC LoRaWAN version of the device The following is an example of a con guration This con guratio...

Страница 38: ...is an example remembering that it is necessary to use the Gateway ID of the ITG 200 you are registering Note The Gateway ID can be found on the ITG 200 s web interface at LoRa Network Server as shown...

Страница 39: ...ateway s web interface according to the Cloud in use by the client Recalling that ports 1883 and 8883 are the standard ports of this protocol 7 2 IT release for the ITG 200 Gateway 7 2 2 HTTP send Whe...

Страница 40: ...e Update Accept ports 443 HTTPS and 7028 from iot khomp com server 7 2 7 PING test Accept the ICMP protocol as the user can at any time from the gateway s web interface System Diagnostics Advanced men...

Страница 41: ...t best describes you 4 Register your e mail address You must use a corporate e mail 5 Fill out the form that was sent to your e mail If you do not receive it in your inbox please check your spam box 6...

Отзывы: