From the front panel:
1. Press
Utilities
>
I/O Config
>
Digital IO
to access the Digital I/O window.
2. Press
Pin 1
to configure Pin 1.
3. Press
Function
and select
Fault Out
. Press
Back
to return to previous page.
4. Configure the polarity for each of the pin. Press
Polarity Pos
to select Positive and
Polarity Neg
to select
Negative.
From the remote interface:
To configure the pin function:
DIG:PIN1:FUNC FAUL
To select the pin polarity:
DIG:PIN1:POL POS
DIG:PIN1:POL NEG
Inhibit input
Pin 3 can be configured as a remote inhibit input. The Inhibit Input function lets an external input signal control the
output state of all the output channels in the power supply. The polarity of pin 3 can also be configured. The input is
level triggered. The signal latency is less than 450 microseconds. Maximum time required for all the output channels
to start to turn off is 45 ms. Pin 4 is the common for pin 3.
The following non-volatile inhibit input modes can be programmed:
LATChing
- causes a logic-true transition on the Inhibit input to disable the output. The output will remain disabled
after the inhibit signal is received.
LIVE
- allows the enabled output to follow the state of the Inhibit input. When the Inhibit input is true, the output is
disabled. When the Inhibit input is false, the output is re-enabled.
OFF
- The Inhibit input is ignored.
From the front panel:
Configure Pin 3 as a remote inhibit input:
1. Press
Utilities
>
I/O Config
>
Digital IO
to access the Digital I/O window.
2. Press
Pin 3
to configure Pin 3.
3. Press
Function
and select
Inhibit In
to configure Pin 3 as a remote inhibit input. Press
Back
to return to previous
page.
4. Configure the polarity for Pin 3. Press
Polarity Pos
to select Positive and
Polarity Neg
to select Negative.
Alternatively, you can configure Pin 3 as a remote inhibit input by pressing
Output Settings
>
Output Inhibit
>
DIO
Pin 3 INH
. In this setting, the polarity is set to Positive by default.
Keysight E36300 Series User's Guide
69
Содержание E36300 Series
Страница 1: ...User s Guide E36300 Series Programmable DC Power Supplies ...
Страница 12: ...12 Keysight E36300 Series User s Guide ...
Страница 29: ...Front panel Rear panel E36312A and E36313A only Keysight E36300 Series User s Guide 29 ...
Страница 106: ...106 Keysight E36300 Series User s Guide ...