53210A Error Messages
A
Keysight 53210A User’s Guide
231
-128
Numeric data not allowed
A number was specified in the command header or in a parameter
where numeric data is not allowed.
-130
Suffix error
An error was detected in the suffix (units) of a numeric parameter,
but more specific information is not available.
-131
Invalid suffix
The parameter suffix is specified incorrectly
(e.g. 10 MZ rather than 10 MHZ).
-134
Suffix too long
A suffix contains more than 12 characters.
-138
Suffix not allowed
A suffix was specified for a numeric parameter when one is not
allowed.
-140
Character data error
A character error was detected in the command header or in a
parameter, but more specific information is not available.
-141
Invalid character data
Either an invalid character was received, or the character is not
valid for the command header.
-144
Character data too long
The character data contains more than 12 characters.
-148
Character data not allowed
A valid character was specified when another data type (numeric,
boolean) is required.
-150
String data error
An error was encountered in the string specified, but more specific
information is not available.
-151
Invalid string data
A required string parameter was received but is invalid.
-158
String data not allowed
A valid string was specified when another data type (numeric,
boolean) is required.
-160
Block data error
An error was encountered in the block data, but more specific
information is not available.
-161
Invalid block data
The number of bytes in a definite length data block does not match
the number of bytes indicated by the block header.
-168
Block data not allowed
A block data element was encountered at an instance where it is
not allowed by the instrument.
-170
Expression error
An error was encountered in a parameter expression, but more
specific information is not available.
-171
Invalid expression
The expression used to calculate a parameter value is invalid.
Table A-1
53210A Error Message Descriptions.
Code
Message
Description
Содержание 53210A
Страница 1: ...Keysight 53210A 350 MHz RF Counter User s Guide ...
Страница 12: ...12 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 18: ...18 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 22: ...22 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 24: ...1 Preparation for Use 24 Keysight 53210A User s Guide Figure 1 1 The 53210A Universal Frequency Counter Timer ...
Страница 48: ...1 Preparation for Use 48 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 122: ...4 53210A Input Signal Conditioning 122 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 222: ...8 Instrument Status 222 Keysight 53210A User s Guide Figure 8 1 The 53210A Status System Instrument Locked Global Error ...
Страница 228: ...8 Instrument Status 228 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...
Страница 240: ...A 53210A Error Messages 240 Keysight 53210A User s Guide THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK ...