background image

Notices

Copyright Notice

© Keysight Technologies 2013 - 2015

No part of this manual may be
reproduced in any form or by any
means (including electronic storage
and retrieval or translation into a foreign
language) without prior agreement and
written consent from Keysight
Technologies, Inc. as governed by
United States and international
copyright laws.

Manual Part Number

Y1299-90004

Published By

Keysight Technologies
Ground Floor and Second Floor, CP-11
Sector-8, IMT Manesar – 122051
Gurgaon, Haryana, India

Edition

Edition 2, July, 2015
Printed In USA

Regulatory Compliance

This product has been designed and
tested in accordance with accepted
industry standards, and has been
supplied in a safe condition. To review
the Declaration of Conformity, go to

http://www.keysight.com/go/conformity

.

Warranty

THE MATERIAL CONTAINED IN THIS
DOCUMENT IS PROVIDED “AS IS,” AND
IS SUBJECT TO BEING CHANGED,
WITHOUT NOTICE, IN FUTURE
EDITIONS. FURTHER, TO THE
MAXIMUM EXTENT PERMITTED BY
APPLICABLE LAW, KEYSIGHT
DISCLAIMS ALL WARRANTIES, EITHER
EXPRESS OR IMPLIED, WITH REGARD
TO THIS MANUAL AND ANY
INFORMATION CONTAINED HEREIN,
INCLUDING BUT NOT LIMITED TO THE
IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE. KEYSIGHT
SHALL NOT BE LIABLE FOR ERRORS
OR FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES IN
CONNECTION WITH THE

FURNISHING, USE, OR
PERFORMANCE OF THIS DOCUMENT
OR OF ANY INFORMATION CONTAINED
HEREIN. SHOULD KEYSIGHT AND THE
USER HAVE A SEPARATE WRITTEN
AGREEMENT WITH WARRANTY TERMS
COVERING THE MATERIAL IN THIS
DOCUMENT THAT CONFLICT WITH
THESE TERMS, THE WARRANTY
TERMS IN THE SEPARATE
AGREEMENT SHALL CONTROL.

KEYSIGHT TECHNOLOGIES DOES NOT
WARRANT THIRD-PARTY SYSTEM-
LEVEL (COMBINATION OF CHASSIS,
CONTROLLERS, MODULES, ETC.)
PERFORMANCE, SAFETY, OR
REGULATORY COMPLIANCE, UNLESS
SPECIFICALLY STATED.

Technology Licenses

The hardware and/or software
described in this document are
furnished under a license and may be
used or copied only in accordance with
the terms of such license.

U.S. Government Rights

The Software is “commercial computer
software,” as defined by Federal
Acquisition Regulation (“FAR”) 2.101.
Pursuant to FAR 12.212 and 27.405-3
and Department of Defense FAR
Supplement (“DFARS”) 227.7202, the
U.S. government acquires commercial
computer software under the same
terms by which the software is
customarily provided to the public.
Accordingly, Keysight provides the
Software to U.S. government customers
under its standard commercial license,
which is embodied in its End User
License Agreement (EULA), a copy of
which can be found at

http://www.keysight.com/find/sweula

. The

license set forth in the EULA represents
the exclusive authority by which the
U.S. government may use, modify,
distribute, or disclose the Software. The
EULA and the license set forth therein,
does not require or permit, among other
things, that Keysight: (1) Furnish
technical information related to
commercial computer software or
commercial computer software
documentation that is not customarily
provided to the public; or (2) Relinquish
to, or otherwise provide, the

government rights in excess of these
rights customarily provided to the
public to use, modify, reproduce,
release, perform, display, or disclose
commercial computer software or
commercial computer software
documentation. No additional
government requirements beyond
those set forth in the EULA shall apply,
except to the extent that those terms,
rights, or licenses are explicitly required
from all providers of commercial
computer software pursuant to the FAR
and the DFARS and are set forth
specifically in writing elsewhere in the
EULA. Keysight shall be under no
obligation to update, revise or otherwise
modify the Software. With respect to
any technical data as defined by FAR
2.101, pursuant to FAR 12.211 and
27.404.2 and DFARS 227.7102, the U.S.
government acquires no greater than
Limited Rights as defined in FAR 27.401
or DFAR 227.7103-5 (c), as applicable in
any technical data.

Safety Notices

A CAUTION notice denotes a hazard. It
calls attention to an operating
procedure, practice, or the like that, if
not correctly performed or adhered to,
could result in damage to the product
or loss of important data. Do not
proceed beyond a CAUTION notice until
the indicated conditions are fully
understood and met.

A WARNING notice denotes a hazard. It
calls attention to an operating
procedure, practice, or the like that, if
not correctly performed or adhered to,
could result in personal injury or death.
Do not proceed beyond a WARNING
notice until the indicated conditions are
fully understood and met.

The following safety precautions should
be observed before using this product
and any associated instrumentation.

This product is intended for use by
qualified personnel who recognize
shock hazards and are familiar with the
safety precautions required to avoid

iii

Содержание RF PA/FEM

Страница 1: ...EM Characterization Test Reference Solution Notice This document contains references to Agilent Please note that Agilent s Test and Measurement business has become Keysight Technologies For more infor...

Страница 2: ......

Страница 3: ...e is customarily provided to the public Accordingly Keysight provides the Software to U S government customers under its standard commercial license which is embodied in its End User License Agreement...

Страница 4: ...onnection to Category I sources unless otherwise marked or described in the user documentation Exercise extreme caution when a shock hazard is present Lethal voltage may be present on cable connector...

Страница 5: ...nd is for use in electromagnetic environments outside of the home A A This product complies with the WEEE Directive marketing requirement The affixed product label above indicates that you must not di...

Страница 6: ...vi...

Страница 7: ...s 17 Cable and Connector Care 18 Prepare the Chassis 19 Install the Controller 20 Embedded Controller 20 Remote Controller 21 Install the M9381A and M9393A Instrument Modules 24 When installing each m...

Страница 8: ...Related Documentation 43 Module Slot Location for the M9381A and M9391A 43 M9391A Cable and Options Table 44 Appendix 2 Updating the M9300A FPGA 46 Reserving the Reference for a Configuration 46 viii...

Страница 9: ...urement with your M9381A VSG and M9393A VSA 7 Optional Verify PA test configuration includes connecting peripheral instru ments for your PA test solution such as Waveform generator SMU etc 8 Installat...

Страница 10: ...Introduction About the RF PA FEM Characterization and Test Reference Solution 10 Keysight Y1299A 004 RF PA FEM Reference Solution Startup Guide...

Страница 11: ...m M9381A device driver API references IVI C IVI COM and LabVIEW G M9381A Data Sheet M9381A Specifications Guide M9393A Vector Signal Analyzer 1 see www keysight com find M9393A M9393A Soft Front Panel...

Страница 12: ...mplifier Test Demo Program User s Guide Keysight PXI Power Amplifier Test Demo Program Developer Guide Recommended Instruments and Software for Power Amplifier Test with Envelope Tracking Signadyne AW...

Страница 13: ...he M9036A if necessary Monitor with M9037A Use the Display Port to VGA adaptor an accessory to the M9037A if necessary USB compatible keyboard USB compatible mouse If you are installing the software f...

Страница 14: ...assemblies The figure left shows a static safe work station using two types of ESD protection conductive table mat and wrist strap combination and conductive floor mat and heel strap combination Both...

Страница 15: ...th the other modules because your instrument may be repaired and calibrated without your M9300A Doing so however will effect your calibration schedule since repairs are followed by calibration The Cal...

Страница 16: ...e shipping label write ATTENTION REPAIR DEPARTMENT and the RMA number In your correspondence refer to the modules by serial number and the instrument by model number Verify Shipment Contents Your solu...

Страница 17: ...t damage to the module All component modules for an M9381A or M9393A instrument are factory tested aligned calibrated and shipped as a bundle It is important that you maintain the bundle when installi...

Страница 18: ...Cable and Connector Care When you need to disconnect push on cables from the module front panel connectors use the Keysight Cable Removal Tool PN 5002 3361 provided in your Keysight PXI instrument s...

Страница 19: ...TO and the inhibit switch is set to DEF 4 Position the chassis to provide ample space between the chassis fan intake and exhaust vents Blockage by walls or obstructions affects the air flow needed for...

Страница 20: ...your solution contains a Keysight M9036A or M9037A Embedded Controller follow the procedure below For additional detail refer to instructions in the M9036A Startup Guide or the M9037A Startup Guide 1...

Страница 21: ...ide The following procedure addresses using the M9021A as a cabled PCIe interface between the M9018A chassis and an external host computer However if you intend to use an M9021A module to control a su...

Страница 22: ...injector ejector handle and making sure the injector ejector handle is pushed down in the unlatched downward position slide the M9021A module into chassis using the slot guides top and bottom b Slidi...

Страница 23: ...ighten the module retaining screws top and bottom and torque them to 5 Lb In 0 57 N m 6 Connect the M9021A to your laptop or desktop PC a If you are using a laptop as a controller connect to your M902...

Страница 24: ...handle is pushed down in the unlatched down ward position slide the module into chassis using the slot guides top and bot tom 2 Sliding the module into position when you begin to feel resistance pull...

Страница 25: ...2 Install the PXI Modules Before installing the PXI Modules Keysight Y1299A 004 RF PA FEM Reference Solution Startup Guide 25 10 M9300A 11 SD AWG H3353 AWG 12 M9195A 13 M9375A VNA 14 M9375A VNA 15 M9...

Страница 26: ...semi rigid SMA male SMA male 8120 5091 M9310A 100 MHz Out to M9311A 100 MHz In Cable coaxial SMB female SMB female 8120 5091 M9310A Trig 1 to M9311A Trig 1 for Pulse Mod Cable coaxial SMB female SMB...

Страница 27: ...mm 8121 2169 M9365A IF Out to M9214A IF In Cable coaxial SMB female SMB female 165 mm 8121 2723 M9300A 100 MHz Out to M9308A 100 MHz In Cable coaxial SMB female SMP female 150 mm 8121 2554 M9308A 100...

Страница 28: ...sight model Y1212A 5 per kit and EMC filler panels Keysight model Y1213A 5 per kit in empty module slots Power up the Chassis If you are using a remote controller you must power up the chassis BEFORE...

Страница 29: ...ller external PC connected to the chassis by a PCI to PXI interface is required Embedded controller Keysight M9036A or M9037A or an embedded controller that meets the following requirements PXIe syste...

Страница 30: ...393A driver 4 M9381A PXIe Vector Signal Generator version 1 4 400 0 or newer www keysight com find M9381A www keysight com find m9381a driver 5 N7624B Signal Studio for LTE LTE Advanced FDD optional w...

Страница 31: ...Startup Guide 31 Order Software NOTE If you are using a remote controller use this sequence to restart the PC and chassis 1 Shut down the PC 2 Power down the chassis 3 Power up the chassis 4 Power up...

Страница 32: ...oftware products that you include in your solution you receive a Software Entitlement Certificate for example Keysight Signal Studio Applications Software Keysight Waveform 5 or 50 packs optional Keys...

Страница 33: ...hannel VSG VSA M9381A and M9393A configuration 1 Turn power on to the M9018A Chassis if you haven t already 2 The step in this process is to conduct a Self Test of the M9381A and the M9393A a Open the...

Страница 34: ...ess or the M9301A is unlocked from the ref erence n a Not connected by the SFP Failure in the power supplies Module hardware health can t be determined until the power supply failure is resolved M9310...

Страница 35: ...s resolved M9308A The Soft Front Panel has initialized the connection to the module Tuning is in progress or the M9308A is unlocked from the ref erence n a Not connected by the SFP Failure in the powe...

Страница 36: ...hat was reported in a Self Test failure go to Utilities Calibration Options to view this screen The string pointed out in this image is the Cal ID The first 10 characters represent the Unique ID and t...

Страница 37: ...rrect Keysight IO Libraries Suite M9381A and M9393A SFP programs Module and chassis drivers System Interface Card cable and PC PXIe card connections if you are using an external host PC If not all mod...

Страница 38: ...esented with the Connect to Instrument dia log Use Ctrl Select to select all of the modules that are components of the M9381A and the M9393A and press Connect 2 Connect a high quality SMA male to SMA...

Страница 39: ...nt Communications Keysight Y1299A 004 RF PA FEM Reference Solution Startup Guide 39 d ALC On checked 5 On the M9393A SFP Measure Tab make the following settings a Frequency 2 GHz b Input Power 10 dBm...

Страница 40: ...ous for a sustained sweep of the analyzer You should see the following display on your SFP The frequency of the signal is 2 GHz and the amplitude is 10 dBm 7 Proceed to Step 7 Installation is Complete...

Страница 41: ...s in a very different end user experience The IVI drivers support compiling application programs for 32 or 64 bit platforms Supported ADEs application development environments Arguably the most import...

Страница 42: ...LabVIEW itself drivers will be installed in the Agilent directory instead of the National Instruments directory for example C Program Files x86 Agilent Agilent product model LabVIEW Driver LabVIEW ve...

Страница 43: ...9391A orM9393A Startup guide M9381A VSG and M9391A VSA Programming Guide M9393A Programmers Guide M9391A device driver API references IVI C IVI COM and LabVIEW G M9393A device driver API references IV...

Страница 44: ...ale SMA female 8120 5091 M9300A 100 MHz Out 1 to M9301A 100 MHz In Cable coaxial SMB female SMB female 120 mm 8120 5091 M9301A 100 MHz Out to M9350A 100 MHz In Cable coaxial SMB female SMB female 120...

Страница 45: ...M9391A F06 F06 Frequency Range 1 MHz to 6 GHz M9391A UNZ Fast Switching M9391A B04 Analysis Bandwidth 40 MHz M9391A B10 Analysis Bandwidth 100 MHz M9391A B16 Analysis Bandwidth 160 MHz M9391A M01 Memo...

Страница 46: ...the hardware configuration so that a subsequent instance will not take control of the reference module unintentionally 1 On the SFP Connect to Instrument screen click the Advanced control to open the...

Страница 47: ...This Page Intentionally Left Blank Keysight Y1299A 004 RF PA FEM Reference Solution Startup Guide 47...

Страница 48: ...This information is subject to change without notice Keysight Technologies 2013 2015 Edition 2 July 2015 Printed In USA Y1299 90004 www keysight com...

Отзывы: