Keysight 16860 Series Portable Logic Analyzer Service Guide
107
Removing, Replacing, or Returning 16860 Series Logic Analyzer Assemblies
6
Back Up Data and License Files
The logic analyzer license files contain keys for licensed software features of logic analyzer. It is
recommended that you back up these license files and any data stored on the logic analyzer’s hard
drive to a USB flash drive before initiating any major repairs to the logic analyzer. The backup copy is
needed to recover data if you encounter any problems that require re-imaging the logic analyzer’s
hard drive.
You can find the license files in the following directories:
C:\Program Files\Keysight Technologies\Logic Analyzer\License\
C:\Program Files\Keysight Technologies\License Server\License Files
For Logic analyzers that use the Keysight License Manager, you can find the license files in the
following directory:
C:\Program Files\Agilent\Licensing\
If you lose the license files, you can obtain new licenses from Keysight Technologies by providing the
licensing host ID.
To obtain the licensing host ID
• From the Keysight Logic and Protocol Analyzer application's main menu, choose
Help
>
Software
Licensing....
The Licensing Host ID is displayed in the
Software Licensing
dialog's
Activation
tab.
• For Logic analyzers that use the Keysight License Manager, you can obtain the Keysight License
Manager Host ID by performing the following steps:
1
From the
Start
menu, choose
All Programs
>
Keysight License Manager
>
Keysight License Manager…
2
The Host ID is shown on the main page. Copy and paste this Host ID into a text file and then
save this file.
Prepare the Logic Analyzer for Disassembly
1 Close the
Keysight Logic and Protocol Analyzer
application.
2 Power off the system using one of the methods described in the table below.
3 Remove the logic analyzer power cord.
4 Move the logic analyzer to a static safe work environment.
Follow cautions and warning listed on
while preparing the Logic Analyzer for disassembly.
To power off the logic analyzer
There are several ways to power off the logic analyzer.
Содержание 16860 Series
Страница 1: ...Keysight 16860 Series Portable Logic Analyzers Service Guide...
Страница 8: ...8 Keysight 16860 Series Portable Logic Analyzer Service Guide...
Страница 12: ...12 Keysight 16860 Series Portable Logic Analyzer Service Guide Contents...
Страница 32: ...3 Testing 16860 Performance 32 Keysight 16860 Series Portable Logic Analyzer Service Guide...
Страница 34: ...3 Testing 16860 Performance 34 Keysight 16860 Series Portable Logic Analyzer Service Guide...
Страница 104: ...5 Troubleshooting 104 Keysight 16860 Series Portable Logic Analyzers Service Guide...
Страница 136: ...7 Replaceable Parts 136 Keysight 16860 Series Portable Logic Analyzer Service Guide...
Страница 138: ...Index 138 Keysight 16860 Series Portable Logic Analyzer Service Guide...