28
COMBI 2
– a mode similar to COMBI; the difference is that when the clearing device
is turned on, the blower always operates with the capacity programmed in the para-
meter BLOWER SPEED RATE AT CLEANING, regardless of the current stage of
operations (except emergencies).
6.2 Cleaning mechanism work time
– this parameter is available only when the
cleaning mechanism is activated (CYCLE, ROTO or COMBI. mode). It defines the ti-
me needed to complete the full mechanism to open or move to end position.
6.3 Cleaning mechanism retraction time
– this parameter is available only when
the cleaning mechanism is activated (CYCLE, ROTO or COMBI. mode). It specifies
the time required for the mechanism retraction to the rest position after turning off
the control output.
6.4 Cleaning mechanism pause time
– this parameter is available only when the
cleaning mechanism is activated (CYCLE, ROTO or COMBI. mode). It specifies the
time interval between successive repetition of the cleaning cycle.
6.5 Opening time cleaning mechanism
– this parameter is only available when
cleaning mechanism operates in AUTO mode or ESTATE and determines the time
required to complete the opening mechanism during cleaning automatic.
6.6 Closing time cleaning mechanism
– This parameter is available only when the
cleaning mechanism operates in AUTO mode or COMBI and determines the time it
takes to return the mechanism to its rest position after the full opening of the auto-
matic cleaning mechanism.