17
Table 3. Table service parameter
F
– parameter depends on the type of fuel.
Lp.
Parametr
Min
Max
F
2.x
Overall
2.1 Language. (see description).
2.2 Brightness of the display.
2.3 Saturation.
2.4 Contrast.
2.5 Service settings.
NO
YES
2.7 Output testing.
NO
YES
3.x
Fan
3.1 Fan modulation during boiler start.
NO
YES
F
3.2 Min. fan speed during heating up.
1%
100%
F
3.3 Max. fan speed during heating up.
1%
100%
F
3.4 Ignition modulation start delay.
0s
250s
F
3.5 Fan speed during ignition.
1%
100%
F
3.6 Fan speed at max. power.
1%
100%
F
3.7 Fan speed at min. power.
1%
100%
F
3.8 Fan speed at extinction.
1%
100%
F
3.9 Fan speed during cleaning mode.
0%
100%
F
3.10 Fan scavenge (air purging).
NO
YES
F
3.11 Fan scavenge (air purging) blow time.
5s
60s
F
3.12 Fan scavenge (air purging) pause time.
1min
99min F
3.13 Fan speed during scavenge.
1%
100%
F
4.x
Auger
4.1 Feeder filling time.
1min
99min F
4.2 Initial fuel feed.
0s
250s
F
4.3 Fuel feed cycle.
1s
250s
F
4.4 Fuel feed during ignition.
0%
100%
F
4.5 Fuel feed for max burner power.
1%
100%
F
4.6 Fuel feed for min. burner power.
1%
100%
F
4.7 Stoker work mode (see description).
4.8 Stoker work time.
1s
99s
4.9 Stoker pause time.
1s
99s
4.10 Stoker extra work time.
1s
99s
4.11 Stoker emptying time.
1s
99s
4.12 Auger ignition test.
NO
YES
4.13 Auger ignition temperature.
20°C
99°C
5.x
Igniter
5.1 Flame detector type: FD–1, PT–1000, CT–1/2.
5.2 CorrectionFD–1.
0
99
F
5.3 Hysteresis loss of flame (temperature sensor).
1°C
250°C F
5.4 Hysteresis loss of flame (optical sensor).
1
255
F
5.5 Flame failure detection delay.
1s
255
F
5.6 Czas rozpalania paliwa.Fuel ignition timea.
1min
15min F
5.7 Ignition try count.
1
10
F
5.8 Test the temperature of the fuel shortage.
20°C
70°C
F
5.9 Fuel shortage testing time.
1min
99min F
5.10 Firing stabilization.
NO
YES
F
5.11 Stabilization time firing up.
1min
99min F
5.12 Smooth stabilization firing.
1min
99min F
5.13 The blanking time the furnace.
1min
30min F
6.x
Cleaning
mechanism
6.1 Mode of operation of the cleaning mechanism: CYCLE,
ROTO, AUTO, COMBI, COMBI2
6.2 Cleaning mechanism work time.
1s
900s
F
6.3 Cleaning mechanism retraction time.
1s
900s
F
6.4 Cleaning mechanism pause time.
1s
900s
F
6.5 Opening time cleaning mechanism.
1s
900s
F