18
6.6 Closing time cleaning mechanism.
1s
900s
F
6.7 Number shut downs before cleaning.
1
99
F
6.8 Minimum operating time without cleaning.
0h
max–1h F
6.9 Maximum working time without cleaning.
min+1h
99h
F
7.x
CH pump
7.1 Central heating pump work mode: TERM, AUTO.
7.2 Central heating pump periodic work.
NO
YES
7.3 Central heating pump periodic work time.
1min
99min
8.x
HTW pump
8.1 Domestic water path: OFF, ON, MIXING PUMP,
8.2 Domestic water heating hysteresis.
1°C
20°C
8.3 Boiler increase temperature during hot tap water heating.
2°C
20°C
F
8.4 Domestic pump work extension.
NO
YES
F
8.5 Domestic pump work extension time.
1min
10min F
8.6 Stabilization time.
1min
99min F
8.7 Mixing pump engaging temperature.
30°C
60°C
F
8.8 Mixing pump work hysteresis.
1°C
9°C
F
9.x
Thermostat
9.1 Boiler minimum temperature.
30°C
69°C
F
9.2 Boiler maximum temperatur.
70°C
90°C
F
9.3 Boiler upper hysteresis.
1°C
20°C
F
9.4 Boiler power switching hysteresis.
1°C
9°C
F
9.5 Boiler protection hysteresis.
1°C
5°C
F
9.6 Boiler overheating temperature.
90°C
99°C
F
9.7 Burner power modulation.
NO
YES
F
9.8 Power modulation factor.
1
20
F
9.9 The operating mode of the thermostat:
NORMAL,ADAPTIVE, WEATHER
F
9.10 The time constant adaptation.
1min
99min F
9.11 Burner switch-off delay.
0min
99min F
9.12 Lowering the thermostat.
0°C
30°C
10.x
Data
transmission
10.1 Data link: (see description). OFF, MODBUS RTU.
10.2 MODBUS device number.
1
247
10.3 MODBUS channel capacity: 2400, 3600, 4800, 7200,
9600, 14400, 19200, 28800,38400, 56000, 57600, 76800,
115200.
10.4 MODBUS frame format: 8N1,8E1, 801, 8N2.
10.5 MODBUS access level: NONE, READOUT,
USER’s, SERVICE.
10.6 Terminal access level: NONE, READOUT,
USER’s, SERVICE.
10.7 Additional delay.
0ms
9.9ms
13.x
Circuit 2
13.1 Circulation mode 2: NO, Mixing. + PUMP, PUMP ONLY.
AUTO
TERM
13.2 Mode switching circuit 2. (see description).
NO
YES
13.3 Weather control.
NO
YES
13.4 Temperature set point circuit.
22°C
40°C
13.5 Lowering the thermostat.
0°C
30°C
13.6 Increasing the temperature of the boiler.
0°C
10°C
13.7 The hysteresis circuit 2.
1°C
9°C
13.8 The minimum temperature circuit 2.
5°C
35°C
13.9 Maximum temperature circuit 2.
36°C
90°C
13.10 The time of the actuator.
2s
99s
13.11 Actuator pause time.
0s
99s
13.12 The transit time of the actuator.
1min
10min
14.x
The heating
curve
14.1 Outside temperature sensor IS, NO
14.2 Point 0 heating curve.
20°C
80°C
14.3 Moving the curve.
0°C
20°C