4.3
Deeper installation and waterproofing
For deeper installation in the floor slab, an additional exten-
sion section (art. no. 83070) must be inserted between the
upper section and the drain body (A).
A maximum installation depth of 650 mm to the top surface
of the functional unit (e.g. the pump) should be observed
for the installation in the floor slab. This way, the necessary
parts can be reached for maintenance and servicing.
Art. no. 83075 must be used (B) for waterproofing against
pressing water (e.g. with waterproof concrete).
4.4
Installation example bituminous membrane (floor slab with separating layer)
1
Aqualift S
2 Seal set art. no. 83073: extension
section with flange and mating
flange (for connection to an on-site
waterproofing sheet)
3 Extension section art. no. 83070
a Floor covering
f Protective con-
crete
b Screed
g Control unit
c Insulation
h Pressure pipe
d Concrete floor
BWS
*)
design
water level
e Waterproofing
layer
*) Maximum groundwater level to be
expected, max. 3 m allowable.
EN
016-059
Lifting station/Installation and operating instructions
25 / 100
Содержание Aqualift S Compact
Страница 6: ...DE 2 5 Funktionsprinzip 6 100 016 059_02 ...
Страница 22: ...EN 2 5 How it works 22 100 Lifting station Installation and operating instructions 016 059 ...
Страница 38: ...FR 2 5 Principe de fonctionnement 38 100 Poste de relevage Instructions de pose et d utilisation 016 059 ...
Страница 70: ...NL 2 5 Werkingsprincipe 70 100 Opvoerinstallatie Inbouw en bedieningshandleiding 016 059 ...
Страница 86: ...PL 2 5 Zasada działania 86 100 Przepompownia Instrukcja zabudowy i obsługi 016 059 ...
Страница 98: ......
Страница 99: ...016 059_02 99 100 ...