DEFINITIONS OF MENU PROMPTS
(continued)
ABBREVIATION
DESCRIPTION
DLY##
DELAY FACTOR - The amount of time (02 to 24 sec.) the unit will "look" for valid data, before the display
defaults to zero. (RATE DISPLAY ONLY)
LOC
LOCK - This portion of the menu allows you to set lock functions (Lock functions apply only to front panel)
1) lock the program (Preset A is still accessible)
2) lock all (locks program & presets; Start & Stop are accessible).
LC PRG
LOCK PROGRAM - This will lock the program. Preset A can be changed, start, stop & reset will function
when the unit is in the lock mode (lock ON).
LC ALL
LOCK ALL - This will lock the program and the presets when the unit is in the locked mode. Preset A can
be viewed, but not changed. Start and Stop buttons will still operate.
CODE
LOCK CODE - This message (code) will flash on display for approximately 3 seconds. It will be followed
by a 5 digit number (xxxxx). The number you enter here will be the code to lock and unlock the unit.
RELAY
RELAY - This portion of the menu allows you to set your relay operation variables.
preuu
PREWARN - When this is selected Relay B energizes when started and drops out at "Preset B" amount
before batch is complete.
TOT
RELAY B FOR TOTALIZER - When this is selected relay B will activate when the selected Grand or
Batch total has reached Preset B.
b##.##
RELAY B DURATION - This message will appear when "TOT" is selected. It is the duration which the
relay will remain energized (00.01 to 99.99 sec). If 00.00 is selected, the relay will latch until reset.
When the duration is not at 00.00, the Grand/Batch totalizer will autorecycle.