11 SCAN
11-5
3 Press [
] (F2) or [
] (F3) to select a Group
for Group Scan.
4 Press [
] (F4), or rotate the MULTI/CH control
to specify whether or not the transceiver scans the
Memory Channels in the grouped Memory Channels.
•
Each key press toggles a tick mark between places (allows
scanning) or removes (does not allow scanning).
•
To start All Channel Scan, place a tick mark on all memory
groups.
•
Pressing [SEL.ALL] (F6) selects and places a tick mark on
all Memory Channels.
•
Pressing [CLR.ALL] (F6) deselects and removes a tick
mark on all Memory Channels.
5 Press [ESC] to exit.
Note:
◆
If the Memory Group to be scanned has been configured as below,
Memory Scan does not start even with the press of [SCAN] (F5).
• Tick marks on all Memory Groups are removed (deselected).
• Even if a tick mark is placed on a Memory Group, no operating
data is stored on the Memory Channels in this Memory Group.
• Even if a tick mark is placed on a Memory Group, all Memory
Channels in this Memory Group are locked out.
◆
The Memory Channels in the Memory Groups are listed below.
Combinations of the Group number and Memory Channel
numbers.
Group
Memory
Channel
Group
Memory
Channel
0
00 to 09
6
60 to 69
1
10 to 19
7
70 to 79
2
20 to 29
8
80 to 99
3
30 to 39
9
90 to 99
4
40 to 49
P
P0 to P9
5
50 to 59
E
E0 to E9
◆
Examples of Configurations for the All Channel Scan and the
Group Scan
• If you place tick marks on Memory Groups 1 and 5, pressing
[SCAN] (F5) starts the Group Scan. The Memory Channels in
Memory Groups 1 and 5 will be scanned.
• If you place tick marks on all Memory Groups, pressing
[SCAN]
(F5) starts the All Channel Scan.
◆
Even if a tick mark is placed for a Memory Channel (the scan is
enabled), the transceiver does not scan the Memory Channel to
which no operating data is stored for the Memory Channel in a
Memory Group or the Memory channel is locked out.
If the transceiver starts scanning while in Dual Memory Channel
mode, the transceiver does not scan the Program Memory
Channels P0 to P9.
LOCKING OUT A MEMORY CHANNEL
You can select Memory Channels to be exempted from
the Memory Scan.
1 Press [M.LIST] (F7) to open the Memory Channel
List screen.
2 Press [
] (F2) or [
] (F3), or rotate the
MULTI/CH control to select a Memory Channel.
3 Press [L.OUT] (F6) to lock out a Memory Channel.
•
A tick mark is placed on the section of "L.OUT" of the
selected Memory Channel.
•
If [L.OUT] (F6) is unavailable in the function key guide,
press [MORE] (F1).
•
Pressing [L.OUT] (F6) again disables the Lockout for the
Memory Channel.
4 Press [ESC] to exit.
Содержание TS-990S
Страница 1: ... B62 2389 10 09 08 07 06 05 04 03 02 01 HF 50 MHz TRANSCEIVER TS 990S INSTRUCTION MANUAL 1 01 ...
Страница 2: ......
Страница 42: ......
Страница 54: ......
Страница 78: ......
Страница 154: ......
Страница 164: ......
Страница 168: ......
Страница 192: ......
Страница 224: ......
Страница 232: ......
Страница 270: ......
Страница 284: ......
Страница 290: ......