 Data sheet MultiSensor-LAN (KMS-LAN)

Connectable devices

Stand-Alone operation (integrated web server)
AlarmManager-PRO

Sensor - temperature

range -40 to 125°C

Sensor - Relative humidity

range 0 to 100%

Dew point

in °C calculated

Sensor - motion

PIR sensor, trigger sensitivity configurable
aperture: ca. 110°
range: ca. 12m

Sensor - carbon monoxide (CO)

0-10.000ppm measurement ± 10%
Internal resolution: 20-200ppm (0-100%)
lifetime approx. 5 years

Buzzer

85dB, 2.3kHz

External alarm input

1 x alarm input (ALARM 1, ALARM 2)
1 x sabotage input
wiring potential free

External alarm output

2 x open collector 0.1A/12V (alarming, remote 
switching)

LED

ALARM (red)
RUN (yellow)
LINK/ACT at the LAN jack

LAN

10/100 Mbit LAN connection
integrated web server

SNMP

(Simple Network Management Protocol)

SNMP V2 (write/read)
SNMP Traps

XML-Output

Actual and historical values

power supply with PoE

12-72VAC/DC power consumption ca. 1.5W
PoE class 1

power supply with power supply unit

10-32VAC/DC power consumption ca. 1.5W over 
system jack

KENTIX system jack

RJ45, for external plug´n play modules (KIO1)

Chassis

Material: PS 90 x 90 x 45 mm
Weight ca. 100g
Color: high white, carbon black

Environmental conditions

Temperature 0 - 60°C
Humidity 5-95%, non condensing

Types

KMS-LAN-B (Chassis Carbon-Black)
KMS-LAN-W (Chassis High-White)

Content of delivery

Mount bracket, Mount material

Accessories

Plug power supply (KOP)
Power-Adapter (KIO1)
Wall mount (KMW)

Page 14                                          

!

(09-2012, subject to change)

!

www.kentix.de

Содержание MultiSensor-LAN

Страница 1: ...User Manual MultiSensor LAN From Firmware Version 2 xx xx...

Страница 2: ...ation Network 6 2 6 Configuration Sensors and Alarm 7 2 7 User accounts and notification 8 2 8 Language 8 2 9 Software update MultiSensor LAN 9 2 10 Copy or save Configuration of MultiSensor LAN 9 2 1...

Страница 3: ...actices Energy and water utility Safety note The installation of the MultiSensors must be run by an competent person In a power failure the settings are not lost Energized relays drop out and go back...

Страница 4: ...t to the power supply over PoE power over ethernet So you can operate the device without another power supply direct by an PoE capable switch The market standard PoE injectors can also be used for pow...

Страница 5: ...hot or exceeded NOK There is a measurement undershot or exceeded an alarm is triggered ON Function or input output status is switched on OFF Function or input output status is switched off Monitoring...

Страница 6: ...larmManager and set the hook FTP server activation The integrated FTP server can be activated or deactivated The FTP access will be needed for a software update of the device Look up in the chapter so...

Страница 7: ...he CO content The measurement is construed to the highest sensitivity and can be changed slightly in the adjustment Carbon Monoxide concentrations like they emerge in fires are detected even at 100 se...

Страница 8: ...me when a triggered alarm shall be triggered The alarm will be sent to the entered e mail addresses until all values are in normal range again A value of 0 sets the alarm repeating to inactive User ac...

Страница 9: ...ate file will be deleted from the filesystem of the MultiSensor IMPORTANT During the update procedure the power supply must not break 7 Now the MultiSensor is accessible and you can see the software v...

Страница 10: ...minutes Current data http MultiSensorIP xml values xml Historical data http MultiSensorIP xml record xml Switch alarm output 2 In the category system you can find a way to turn on the alarm output 2...

Страница 11: ...nsor there where is also the config ini file After a reboot the configured command sequence will send to the camera in case of an alarm Up to five cameras can be controlled create for each camera a ne...

Страница 12: ...The alarm inputs of the device are only on System connector 1 of the terminal connection of the KIO1 adapter available Page 12 09 2012 subject to change www kentix de IMPORTANT The switching outputs 6...

Страница 13: ...port side forward 3 Pull the lid at the sides apart sightly see picture 4 The lid will snap out from the surrounding groove with a clicking noise 5 Now you can pull up the lid Close the device lid 1 L...

Страница 14: ...RM red RUN yellow LINK ACT at the LAN jack LAN 10 100 Mbit LAN connection integrated web server SNMP Simple Network Management Protocol SNMP V2 write read SNMP Traps XML Output Actual and historical v...

Страница 15: ...facturers websites Copyright Notice All rights reserved Any text images graphics animations and videos as well as content and structure of this manual are protected by copyright and other laws protect...

Отзывы: