GENERAL INFORMATION

The central vacuum is designed for dry pick-up of household dirt and 
dust. Avoid picking up hard or sharp objects with this system to prevent 
hose and plastic pipe damage or clogs. 

This manual will cover the final steps of installation of the power unit in 
your home. It will also provide the necessary information for maintenance 
and trouble shooting, in the unlikely event that it will be needed. If you 
require further information about installation or inquires on the product 
please contact your local authorized dealer/distributor.

INSTALLATION SAFETY EqUIPMENT 

For wall preparations and cover preparations,  
safety equipment such as helmet, gloves, goggles  
and hearing protection are recommended.

CAUTION

 

 

Use caution when drilling holes in walls as gas pipelines and water pipes 
and electrical wires may be present. 

If you have any questions regarding the product, spare parts, service, warranty 
or anything else, please contact your local authorized dealer or distributor.

GROUNDING INSTRUCTIONS

This appliance must be grounded. If it should malfunction or brake down, 
grounding provides a path of least resistance for electrical current to reduce 
the risk of electrical shock. This appliance is equipped with a cord having 
an equipment-grounding conductor and grounding plug. The plug must 
be plugged into an appropriate outlet that is properly installed and 
grounded in accordance with all local codes and ordinances. 

WARNING

Improper connection of the equipment-grounding conductor can result in 
electrical shock. Check with a qualified electrician or service person if you are 
in doubt as to whether the outlet is properly grounded, or if the outlet does 
not fit into an outlet. Do not modify the plug provided with the appliance. 

This appliance is for use on a nominal 120 volt circuit and has a grounding 
plug that looks like the plug illustrated in Figure A. Make sure that the appliance 
is connected to an outlet having the same configuration as the plug.  
No adapter should be used with the appliance.

NOTE:

 In Canada, the use of a temporary adapter  

is not permitted by the Canadian Electrical Code.

WARNING

 

If the supply cord is damaged, it must be replaced by a special cord 
available from your local authorized dealer/distributor. 

SERVICE INFORMATION

The instructions in this booklet serve as a guide to routine maintenance. For 
additional information, contact you’re nearest authorized dealer/distributor.

RATING PLATE

The type, model, and serial numbers are indicated on the rating plate  

located on the control panel or motor hood. For prompt and complete service 
information, always refer to these numbers when inquiring about service.

WARNING

Non-observance of the safety directions may result in bodily harm. 

PRODUCT DIMENSIONS

Refer to page 15 - Image 1

WASTE OF ELECTRIC AND ELECTRICAL  

EqUIPMENT (WEEE)

This symbol on the product or on its packaging indicates that this product 
may not be treated as household waste. Instead it should be handed over 
to applicable collection point for the recycling of electronics and electrical 
equipment. By ensuring this product is disposed of correctly, you will help 
prevent potential negative consequences for the environment and human 
health, which could otherwise be caused by inappropriate waste handling 
of this product. For more detailed information about this product, please 
contact your local waste disposal service or the shop where you purchased 
the product.

INSTALLATION

Your home is most likely already fitted with the system of plastic pipes 
and inlet valves and you are ready to install the central power unit. If your 
home is not fitted for a central vacuum system, you can contract to have 
the Kenmore Central Vacuum System installed by a professional by 
contacting your local dealer or distributor or choose to do-it-yourself. 

The central power unit should be located as far away from the general living 
area as possible, yet accessible so you can remove the dirt receptacle, reach 
the filter, and inspect the central power unit.  A typical location would be in a 
garage, where you could vacuum your car or garage area, and where emptying 
the dirt receptacle and cleaning the filter would be more convenient. Other suit-
able locations are in the basement, laundry room, or ventilated storage room. 

CAUTION

 

Use caution when drilling holes in walls as gas pipelines and water pipes 
and electrical wires may be present. Holes in the masonry are only  
allowable if through it its standing stability is not impaired. Holes in wood 
studs should be drilled. Depending on what material your home is  
built with, use the appropriate anchors to hang your power unit. Power unit 
simply slides onto mounting bracket and clicks into place.

Refer to page 15 - Image 3

•  Place the central power unit in a place that is removed from the general 

living area. The exhaust should be easy to connect to a ventilation pipe. 
This can be done regardless of the house’s construction material.

•  Locate the two low voltage wires near the main pipe. Remove the 

insulation from the low volt wire. Insert the low volt wire into the spring 
loaded low volt connectors. Be certain you comply with your local 
electrical codes and regulations.

Refer to page 15 - Image 4 

•  Make sure there is a dedicated electric socket for the power unit.

•  Plug in your CVS with the supplied power cord.

Содержание TYPE K

Страница 1: ...Central Vacuum Systems Owner s Manual Type K Système central d aspiration Manualdupropriétaire Type K 460445 ...

Страница 2: ...king as it should has been dropped damaged left outdoors or dropped in water return it to a service center Connect to a properly grounded outlet only refer to grounding instructions Do not use extension cords or outlets with inadequate current carrying capacity Turn off all controls before unplugging Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not handle plug or cord ...

Страница 3: ...ood For prompt and complete service information always refer to these numbers when inquiring about service WARNING Non observance of the safety directions may result in bodily harm PRODUCT DIMENSIONS Refer to page 15 Image 1 WASTE OF ELECTRIC AND ELECTRICAL EQUIPMENT WEEE This symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it sho...

Страница 4: ...o allow suction to decrease thus protecting the inlet valve seal Refer to page 15 Image 8 LED Indications Optional Depending on model You machine may be equipped with some or all of the indicators listed below Refer to page 15 Image 9 On Off Motor Fault Dirt Receptacle Full Reset Your power unit is equipped with a multi color LED panel This LED panel will provide you with necessary information on ...

Страница 5: ...life monitor measure or most recent recorded power level To scroll through these features simply push the button corresponding with the right pointing arrow symbol The next screen you will see will be the Life Meter Scroll right further and you will find Bucket Status Yet another scroll will show you last recorded performance levels of the power unit using the Performance Meter on the In Use scree...

Страница 6: ... the hose obstruction insert a blunt instrument into the hose garden hose wood dowel You can also attempt to reverse the suction through the hose to dislodge the blockage Refer to page 15 Image 12 and 13 If there is one inlet valve without normal suction and you have checked for hose blockage then the blockage is in the pipe system between the blocked inlet valve and the power unit see instruction...

Страница 7: ... tools fail to perform due to manufacturing defects return it to your nearest Sears service depot and they will repair or replace free of charge Limitations and Exclusions This warranty does not apply to products purchased outside Canada or to any product which has been improperly installed and or assembled subjected to usage for which the product has was not designed misused or abused damaged dur...

Страница 8: ...centre de service Branchez le dans un prise de courant correctement mise à la terre seulement consultez la section Instructions pour mise à la terre N utilisez pas de cordons de rallonge ou de prise dont l intensité de courant admissible n est pas acceptable Fermez toutes les commandes avant de débrancher Ne débranchez pas en tirant sur le cordon Pour débrancher tirez la fiche pas le cordon Ne man...

Страница 9: ...es instructions contenues dans ce manuel servent de guide pour l entretien de routine Pour plus d information communiquez avec votre détaillant ou distributeur autorisé local PLAQUE SIGNALÉTIQUE Le type et les numéros de modèle et de série sont indiqués sur la plaque signalétique qui se trouve sur le panneau de commandes ou sur le capot du moteur Pour obtenir rapidement des informations complètes ...

Страница 10: ...aire Pour un contrôle ultime de la qualité de l air optez pour la série 650 La série 650 est dotée d un filtre HEPA authentique et peut être intégrée à l unité motrice que vous choisissez ou peut être achetée chez un détaillant ou un distributeur autorisé Vous n avez qu à fixer le filtre HEPA authentique tel que montré Voir à la page 15 Image 7 VÉRIFICATION DU SYSTÈME Assurez vous que votre instal...

Страница 11: ...gression de la performance apparaîtront Lorsqu une unité motrice fonctionne normalement les 4 barres de performance devraient être allumées S il y a constamment moins de 2 barres vous devriez vérifier quel est le problème 1 Blocage de la succion à l extrémité du boyau 2 Obstruction dans la tuyauterie du système 3 Utilisation d un accessoire à débit d air restreint par exemple un outil de coin 4 Cu...

Страница 12: ...our les modèles à ACL l écran clignotera jusqu à ce que le problème cesse Si le problème persiste communiquez avec votre détaillant ou distributeur autorisé L unité motrice a besoin d un temps de refroidissement de 30 minutes avant d être redémarrée Voir à la page 15 Image 9 DIAGNOSTICS ET MAINTENANCE Une réduction du débit d air ou de la succion indique que le système central d aspiration ne fonc...

Страница 13: ...a un fusible sauté ou un disjoncteur déclenché dans la boîte d alimentation principale de la maison Débranchez l unité motrice et vérifiez tous les branchements des prises d admission et toutes les connexions à basse tension pour vous assurer que tous les fils sont bien fixés Si l unité motrice ne démarre toujours pas communiquez avec le détaillant ou le centre de service autorisé le plus près UNI...

Страница 14: ...blement à cause de défauts de fabrication rapportez le à votre centre de service Sears le plus près et ils le répareront ou le remplaceront sans frais LIMITATIONS ET EXCLUSIONS Cette garantie ne s applique pas aux produits achetés à l extérieur du Canada ni à un produit qui a été incorrectement installé et ou assemblé soumis à un usage pour lequel le produit n a pas été conçu ou à un usage abusif ...

Страница 15: ...n 70 cm 27 5 Maximum 1 8 m 6 from outlet de la prise de courant Min 30 cm 12 Min 30 cm 12 Min 30 cm 12 LCD Screen Écran ACL LED Buttons On Off Empty Dirt Receptacle Marche arrêt Cuve à poussière pleine Motor Status Reset État du moteur Réenclenchement 103 2 cm 40 5 49 5 cm 19 5 ...

Страница 16: ...ine Pour la réparation des appareils électroménagers de grandes marques à votre domicile peu importe le fabricant ou le détaillant Pour connaître l emplacement du Service des pièces et de l entretien Sears le plus proche afin d apporter à l atelier des produits tels que des aspirateurs tondeuses à gazon ou appareils électroniques Pour connaître le n de téléphone du Service des pièces et de l entre...

Отзывы: