Kenmore TYPE K Скачать руководство пользователя страница 6

6

receptacle, press the buttons on the receptacle handles. Remove and empty 
the contents. Return the receptacle by attaching the bucket to the power 
unit. To avoid suction loss make sure the receptacle is securely attached.

Refer to page 15 - Image 11

FILTER MAINTENANCE

The Kenmore filter is permanent and self cleaning. However, if you have 
questions about your permanent self-cleaning filter, please contact your 
local authorized dealer/distributor.

PAPER BAG FILTERS

 - OPTIONAL

The volume of the paper bag is 22 liters. A full dust bag reduces the 
systems performance. Depending on how often you use your central 
vacuum system, the dust bag may need to be changed 2-3 times  
per year – and can be obtained at your local dealer/distributor. 

Instructions for changing the dust bag:

1. Remove the power unit dirt receptacle

2. Loosen the dust bag from the intake tube, remove and dispose.

3. Place and press the new dust bag firmly into the tube.  

Turn the dust bag’s opening to make it fasten firmly on the tube. 

4. Put the dirt receptacle back on the central power unit.

IF YOU ExPERIENCE TROUBLE WITH YOUR  

KENMORE CENTRAL VACUUM SYSTEM, FOLLOW 

THE SUGGESTIONS BELOW BEFORE CALLING 

FOR SERVICE.

PARTIAL/TOTAL LOSS OF SUCTION POWER 

•  Be sure dirt receptacle is on properly.

•  Empty dirt receptacle.

•  Remove debris from filter.

•  Be sure each inlet valve is properly closed.

CLEAR BLOCKAGE IN PIPES

Blockage in the hose

Plug hose into any inlet valve. If there is no suction through the hose after 
connecting at a couple of inlets, the blockage is in the hose. To clear the 
hose obstruction, insert a blunt instrument into the hose (garden hose, 
wood dowel). You can also attempt to reverse the suction through the 
hose to dislodge the blockage. 

Refer to page 15 - Image 12 and 13

If there is one inlet valve without normal suction and you have checked 
for hose blockage, then the blockage is in the pipe system between the 
blocked inlet valve and the power unit (see instructions below).

Insert the hose into the inlet valve where there is no suction; hold your 
hand over the hose end. Release hand quickly. Repeat several times. If 
blockage does not clear, contact your nearest Kenmore dealer/distributor. 

POWER UNIT WILL NOT START

•  Check for blown fuse or circuit breaker in main house electric supply box. 

•  Unplug and check all wall inlet and low voltage connections for loose wires.

•  If unit still will not start, contact your nearest authorized service  

station/dealer.

POWER UNIT WILL NOT STOP

•  Check inside each inlet valve for obstruction of low-voltage contacts.  

If no visual obstruction can be detected, disconnect the cleaner from 
the power receptacle and contact your nearest service station/dealer.

CENTRAL POWER UNIT SHUTS OFF BY ITSELF 

•  Remove and then re-insert hose into inlet or toggle switch off-on 

located on hose handle. See “Overload Protection”.

Instructions to install utility inlet – optional

Instructions pour l'installation de la prise utilitaire – optionnelle

PVC pipe Insert (length optional)

Raccord de tuyau en PVC

(longueur facultative)

Power unit

Unité motrice

PVC pipe to system

Tuyau en PVC raccordé 

au système

Sweep 90 tee

Té évasé à 90 degrés

Inlet valve (low voltage)

Prise utilitaire

(à basse tension)

Low voltage wire to cleaner control box

Fil à basse tension au panneau de commandes 

de l'aspirateur

Содержание TYPE K

Страница 1: ...Central Vacuum Systems Owner s Manual Type K Système central d aspiration Manualdupropriétaire Type K 460445 ...

Страница 2: ...king as it should has been dropped damaged left outdoors or dropped in water return it to a service center Connect to a properly grounded outlet only refer to grounding instructions Do not use extension cords or outlets with inadequate current carrying capacity Turn off all controls before unplugging Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not handle plug or cord ...

Страница 3: ...ood For prompt and complete service information always refer to these numbers when inquiring about service WARNING Non observance of the safety directions may result in bodily harm PRODUCT DIMENSIONS Refer to page 15 Image 1 WASTE OF ELECTRIC AND ELECTRICAL EQUIPMENT WEEE This symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it sho...

Страница 4: ...o allow suction to decrease thus protecting the inlet valve seal Refer to page 15 Image 8 LED Indications Optional Depending on model You machine may be equipped with some or all of the indicators listed below Refer to page 15 Image 9 On Off Motor Fault Dirt Receptacle Full Reset Your power unit is equipped with a multi color LED panel This LED panel will provide you with necessary information on ...

Страница 5: ...life monitor measure or most recent recorded power level To scroll through these features simply push the button corresponding with the right pointing arrow symbol The next screen you will see will be the Life Meter Scroll right further and you will find Bucket Status Yet another scroll will show you last recorded performance levels of the power unit using the Performance Meter on the In Use scree...

Страница 6: ... the hose obstruction insert a blunt instrument into the hose garden hose wood dowel You can also attempt to reverse the suction through the hose to dislodge the blockage Refer to page 15 Image 12 and 13 If there is one inlet valve without normal suction and you have checked for hose blockage then the blockage is in the pipe system between the blocked inlet valve and the power unit see instruction...

Страница 7: ... tools fail to perform due to manufacturing defects return it to your nearest Sears service depot and they will repair or replace free of charge Limitations and Exclusions This warranty does not apply to products purchased outside Canada or to any product which has been improperly installed and or assembled subjected to usage for which the product has was not designed misused or abused damaged dur...

Страница 8: ...centre de service Branchez le dans un prise de courant correctement mise à la terre seulement consultez la section Instructions pour mise à la terre N utilisez pas de cordons de rallonge ou de prise dont l intensité de courant admissible n est pas acceptable Fermez toutes les commandes avant de débrancher Ne débranchez pas en tirant sur le cordon Pour débrancher tirez la fiche pas le cordon Ne man...

Страница 9: ...es instructions contenues dans ce manuel servent de guide pour l entretien de routine Pour plus d information communiquez avec votre détaillant ou distributeur autorisé local PLAQUE SIGNALÉTIQUE Le type et les numéros de modèle et de série sont indiqués sur la plaque signalétique qui se trouve sur le panneau de commandes ou sur le capot du moteur Pour obtenir rapidement des informations complètes ...

Страница 10: ...aire Pour un contrôle ultime de la qualité de l air optez pour la série 650 La série 650 est dotée d un filtre HEPA authentique et peut être intégrée à l unité motrice que vous choisissez ou peut être achetée chez un détaillant ou un distributeur autorisé Vous n avez qu à fixer le filtre HEPA authentique tel que montré Voir à la page 15 Image 7 VÉRIFICATION DU SYSTÈME Assurez vous que votre instal...

Страница 11: ...gression de la performance apparaîtront Lorsqu une unité motrice fonctionne normalement les 4 barres de performance devraient être allumées S il y a constamment moins de 2 barres vous devriez vérifier quel est le problème 1 Blocage de la succion à l extrémité du boyau 2 Obstruction dans la tuyauterie du système 3 Utilisation d un accessoire à débit d air restreint par exemple un outil de coin 4 Cu...

Страница 12: ...our les modèles à ACL l écran clignotera jusqu à ce que le problème cesse Si le problème persiste communiquez avec votre détaillant ou distributeur autorisé L unité motrice a besoin d un temps de refroidissement de 30 minutes avant d être redémarrée Voir à la page 15 Image 9 DIAGNOSTICS ET MAINTENANCE Une réduction du débit d air ou de la succion indique que le système central d aspiration ne fonc...

Страница 13: ...a un fusible sauté ou un disjoncteur déclenché dans la boîte d alimentation principale de la maison Débranchez l unité motrice et vérifiez tous les branchements des prises d admission et toutes les connexions à basse tension pour vous assurer que tous les fils sont bien fixés Si l unité motrice ne démarre toujours pas communiquez avec le détaillant ou le centre de service autorisé le plus près UNI...

Страница 14: ...blement à cause de défauts de fabrication rapportez le à votre centre de service Sears le plus près et ils le répareront ou le remplaceront sans frais LIMITATIONS ET EXCLUSIONS Cette garantie ne s applique pas aux produits achetés à l extérieur du Canada ni à un produit qui a été incorrectement installé et ou assemblé soumis à un usage pour lequel le produit n a pas été conçu ou à un usage abusif ...

Страница 15: ...n 70 cm 27 5 Maximum 1 8 m 6 from outlet de la prise de courant Min 30 cm 12 Min 30 cm 12 Min 30 cm 12 LCD Screen Écran ACL LED Buttons On Off Empty Dirt Receptacle Marche arrêt Cuve à poussière pleine Motor Status Reset État du moteur Réenclenchement 103 2 cm 40 5 49 5 cm 19 5 ...

Страница 16: ...ine Pour la réparation des appareils électroménagers de grandes marques à votre domicile peu importe le fabricant ou le détaillant Pour connaître l emplacement du Service des pièces et de l entretien Sears le plus proche afin d apporter à l atelier des produits tels que des aspirateurs tondeuses à gazon ou appareils électroniques Pour connaître le n de téléphone du Service des pièces et de l entre...

Отзывы: