Troubleshooting
BubbleSpa® Overhead Shower
Before troubleshooting, ensure that the correct installation, usage and maintenance procedures have been followed.
Improper installation and improper use of the product can cause a lot of issues. The guide below is designed to help identify
and solve minor issues which may occur. If the issue is still not resolved, please contact Kelda Customer Service:
[email protected]
+44 (0)2381 290640
DO NOT
disassemble the BubbleSpa® Overhead Shower beyond the instructions contained in this manual. Disassembling
the BubbleSpa® Overhead Shower will invalidate the warranty.
Symptom
Likely Cause
Action/ Remedy
Poor/ no water flow:
Hot or cold water supply
isolation valve closed
Blocked filter
Mixer valve not functioning
Check and open valve
Clean/ replace the filter in the Overhead Shower (see
page 26)
Check mixer valve
Water flows from Overhead
Shower but no air:
No power to the fan
Fan Damaged
Debris in fan
Check power light indicator, if off contact a qualified
electrician
Overhead Shower has entered Fan Protection Mode
(see page 23)
If on, conduct hard reset by switching off electrical
supply and waiting 10 seconds before switching back
on
Use Diagnostic Function to see if the fan is working. If
not, contact Kelda
Clean the Dust Filters
One/ a few nozzles aren’t
making bubbles:
No laminar flow through nozzle
Faulty nozzle is blocked
Insufficient water supply
Gently brush a finger against the nozzle whilst the
shower is running
Descale the Overhead Shower to remove debris (see
page 25). Check the filter is installed correctly (both in
the Overhead Shower and in the valve)
Clean/ replace the filter in the Overhead Shower (see
page 26)
Increase the water flow to the shower.
Multiple/ all nozzles aren’t
making bubbles
Insufficient water supply
Limescale/ Debris build up in the
nozzles
The fan wont turn on below 6L/min therefore no
bubbles will be produced. Clean/ replace the filter in
the Overhead Shower (see page 26). Increase the
water flow to the shower.
Descale the BubbleSpa® Overhead Shower (see page
25).
It is reccomended not to leave the BubbleSpa®
Overhead Shower unused for more than 2 weeks.
Water flow too strong:
Flow restrictor not installed.
Check if the flow restrictor is properly installed (see
page 26)
Water leaking from
Overhead Shower when
the valve is turned off/
closed
This can be normal for a short
period time after the shower has
been used
Pressure has exceeded that
stated for the product
Flow valve leaking
N/A
Please refer to technical data and adjust as neccessary
Remove and check the Flow Cartridge of the mixer