Installing the Software
3-5
Setting the Base Address
The base address switch is preset at the factory for a hexadecimal value of
300 (768 decimal). If this address appears to conflict with the address of
another device in the computer (including other DAS-1800HC Series
boards), you must reset the base address switch.
The base address switch is a 7-position DIP switch located as shown in
Figure 3-1. To reset this switch for another address, use DriverLINX
software configuration (see “DriverLINX Configuration Notes” on page
C-1), to determine the new switch settings. The settings for the base
address switch must match the settings in the DriverLINX program.
Note:
The settings for the base address switch must match the settings
shown in DriverLINX.
Figure 3-1. Location of Base Address Switch
Hex value when switch
is in down position:
200
100
80
20
8
40
10
Value of Hex 300
(768 decimal) shown
DAS-1800HC Series Board
Installing the Software