The Model 2000 can be configured to accept device-dependent commands of the Keithley
Models 196/199. The commands to control the Model 2000 with the 196/199 language are pro-
vided in Table D-1.
Since the architecture of the Model 2000 differs from that of the 196/199, some commands
are different or cannot be used. Commands such as function (offset-compensated ohms, AC cur-
rent dB), range, analog and digital filter, rate, calibration, factory defaults, and self-test do not
map one-for-one. Also note that the Model 2000 does not have the speed characteristics of the
Models 196/199. Other commands of the Model 2000 have been added to the 196/199 command
set, such as frequency, temperature, and scanning. Refer to the appropriate manual for further
details.
CAUTION
The 196/199 language is intended to be used only over the IEEE-488 bus.
Using front panel controls in conjunction with this language may cause
erratic operation. In this case, results cannot be guaranteed.
Table D-1
Models 196/199 device-dependent command summary
Mode
Command
Description
Execute
X
Execute other device-dependent commands.
Function
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
DC volts
AC volts
2-wire ohms
DC current
AC current
ACV dB
Not valid
Frequency
Temperature
4-wire ohms
Range
R0
R1
R2
R3
R4
R5
R6
R7
DCV ACV
DCA ACA
Ohms* ACV dB
Freq
Auto Auto
Auto Auto
Auto
Auto
—
1V
1V 100mA
1A
1k
Ω
1V
.1V
10V
10V
3A
3A
10k
Ω
10V
1V
100V 100V
3A
3A
100k
Ω
100V
10V
1000V 750V
3A
3A
1M
Ω
750V 100V
1000V 750V
3A
3A
10M
Ω
750V 750V
1000V 750V
3A
3A 100M
Ω
750V
—
1000V 750V
3A
3A 100M
Ω
750V
—
*2-wire and 4-wire ohms
Zero (Rel)
Z0
Z1
Z2
Zero disabled
Zero enabled
Zero enabled using a zero value (V)
Filter
P0
P1
P2
Filter disabled
Moving filter (count = 10)
Repeat filter (count = 10)
D-2
Models 196/199 and 8840A/8842A Commands
Содержание 2000
Страница 1: ...Model 2000Multimeter User s Manual A G R E A T E R M E A S U R E O F C O N F I D E N C E...
Страница 13: ...1 General Information...
Страница 19: ...2 Basic Measurements...
Страница 54: ...2 36 Basic Measurements...
Страница 55: ...3 Measurement Options...
Страница 87: ...4 Remote Operation...
Страница 139: ...5 SCPI CommandReference...
Страница 215: ...A Specifications...
Страница 226: ...A 12 Specifications...
Страница 227: ...B Statusand ErrorMessages...
Страница 233: ...C Example Programs...
Страница 246: ...C 14 Example Programs...
Страница 247: ...D Models196 199and 8840A 8842ACommands...
Страница 255: ...E IEEE 488 BusOverview...
Страница 271: ...F IEEE 488andSCPI ConformanceInformation...