background image

RAPT Temperature Controller Instruction Manual 

 

Page 

16

 of 

17

 

www.KegLand.com.au

 

Last Updated 24/05/2022 12:17 PM

 

 

Troubleshooting Registration and Telemetry 

The default setting for telemetry is 60 minutes. As a result, you will not see telemetry in the RAPT 
Portal right away. 

 

Should the telemetry data not appear, then you may need to re-register your RAPT Temperature 
Controller with the RAPT Portal. 

No telemetry is displayed on the RAPT Poral 

If you are experiencing issues receiving telemetry or sending a profile to your RAPT Temperature 

Controller from the RAPT portal then you should first check that your RAPT Temperature controller 

controller is connected to your Wi-Fi network. 

Determine whether your RAPT Temperature Controller is connected to Wi-Fi and check the 
signal strength 

To check your BrewZilla Gen 4.0 controller is connected to your Wi-Fi network with good signal 

strength press ‘Select’ and navigate to the 

Settings

 and then 

Diagnostics

.  

The Wi-Fi strength will be displayed in this Diagnostics menu and the Wi-Fi network which the 

controller is connected to will be shown next to wifi AP. 

Signal strength is represented on a scale of 0 to -100dbm 

 

 

 

 

 

Re-register your RAPT Temperature Controller 

If your RAPT Temperature Controller is still not sending telemetry to the RAPT Portal or you are 

unable to remotely start a profile despite being connected to Wi-Fi with a good, reliable signal 

strength then you may need to re-register your RAPT Temperature Controller to your account. To 

re-register your BrewZilla controller do not delete the device from the RAPT Portal, instead follow 

the steps below: 

1.

 

Go to the 

settings

 menu on your RAPT Temperature Controller.

 

2.

 

Navigate to 

clear registration 

and press select (

).

 

3.

 

Register your device to your RAPT account according to the instructions on page 3.

 

Signal Strength (dBm) 

What it means 

0 to -30dBm 

Maximum signal 

-50dBm 

Excellent signal 

-67dBm 

Good, reliable signal 

-70dBm 

Ok, not a strong signal  

-80dBM 

Poor, unreliable signal 

-90dBM 

Unusable 

Содержание RAPT KL22927

Страница 1: ...RAPT Temperature Controller Instruction Manual Page 1 of 17 www KegLand com au Last Updated 24 05 2022 12 17 PM RAPT Temperature Controller KL22927 Instruction Manual KegLand Distribution PTY LTD...

Страница 2: ...mperature Profile on the RAPT Temperature Controller 6 Operation Instructions 7 Manual Operation 8 Setting the Target Temperature 8 Starting a Saved Temperature Profile 8 Mounting your RAPT Temperatur...

Страница 3: ...Legend Graph Enabled Display Legend Graph Disabled The display on the RAPT Temperature controller will display a graph of temperature vs time by default If instead you prefer a numerical old school in...

Страница 4: ...RAPT Temperature Controller Instruction Manual Page 4 of 17 www KegLand com au Last Updated 24 05 2022 12 17 PM...

Страница 5: ...ectivity of the RAPT Temperature Controller you will need to sign up for an account on the RAPT portal This will allow you to create custom fermentation profiles track and monitor your fermentation te...

Страница 6: ...displayed will be the set point for the device The RAPT Temperature controller will then automatically turn on off the heating and or cooling devices plugged into the outlets as required The temperatu...

Страница 7: ...ges automatically when the profile is started manually through the controller Operation Instructions 1 Sign up for an account on the RAPT Portal 2 Connect your RAPT Temperature Controller to your Wi F...

Страница 8: ...ws to adjust the target temperature The temperature controller will then automatically send power to the heating or cooling terminals to power on your heating or cooling device to maintain this target...

Страница 9: ...r to mount the controller onto the wall for example Removing the Mounting Plate To remove the mounting plate slide the mounting plate down towards the bottom of the controller Wall Mounting Option 1 I...

Страница 10: ...r wall for example Wall Mounting Option 4 Another option for mounting the RAPT Temperature Controller onto a wall is to drill a screw through the recessed holes below the front face plate which contin...

Страница 11: ...lugged from the wall socket before changing the orientation of the cables If you want to neatly mount the RAPT Temperature controller vertically onto your bench or into a custom designed cabinet panel...

Страница 12: ...ecure with screws You can then custom design your own panel or cabinet to mount this temperature controller into with the outlets and wiring now exiting out the back of the controller allowing for a v...

Страница 13: ...ate to the advanced setting you need to adjust and press select on this setting Then use the Up or Down arrow to adjust the set value for the setting Default Settings SETTING DEFAULT MIN MAX Cooling H...

Страница 14: ...g Firmware Your RAPT Temperature Controller will automatically check for and install firmware updates when turned on and connected to a Wi Fi network To check the firmware version on your RAPT Tempera...

Страница 15: ...ad thermometer KL23320 Wait for the temperature reading on both the RAPT Temperature Controller and the external calibrated thermometer to stabilise as much as possible Then adjust the temperature sho...

Страница 16: ...s Select and navigate to the Settings and then Diagnostics The Wi Fi strength will be displayed in this Diagnostics menu and the Wi Fi network which the controller is connected to will be shown next t...

Страница 17: ...ww KegLand com au Last Updated 24 05 2022 12 17 PM If you are unable to sign up an account or your RAPT Fermentation Fridge or RAPT portal displays an error please forward as many visual pieces of sup...

Отзывы: