RAPT Temperature Controller Instruction Manual
Page
16
of
17
Last Updated 24/05/2022 12:17 PM
Troubleshooting Registration and Telemetry
The default setting for telemetry is 60 minutes. As a result, you will not see telemetry in the RAPT
Portal right away.
Should the telemetry data not appear, then you may need to re-register your RAPT Temperature
Controller with the RAPT Portal.
No telemetry is displayed on the RAPT Poral
If you are experiencing issues receiving telemetry or sending a profile to your RAPT Temperature
Controller from the RAPT portal then you should first check that your RAPT Temperature controller
controller is connected to your Wi-Fi network.
Determine whether your RAPT Temperature Controller is connected to Wi-Fi and check the
signal strength
To check your BrewZilla Gen 4.0 controller is connected to your Wi-Fi network with good signal
strength press ‘Select’ and navigate to the
Settings
and then
Diagnostics
.
The Wi-Fi strength will be displayed in this Diagnostics menu and the Wi-Fi network which the
controller is connected to will be shown next to wifi AP.
Signal strength is represented on a scale of 0 to -100dbm
Re-register your RAPT Temperature Controller
If your RAPT Temperature Controller is still not sending telemetry to the RAPT Portal or you are
unable to remotely start a profile despite being connected to Wi-Fi with a good, reliable signal
strength then you may need to re-register your RAPT Temperature Controller to your account. To
re-register your BrewZilla controller do not delete the device from the RAPT Portal, instead follow
the steps below:
1.
Go to the
settings
menu on your RAPT Temperature Controller.
2.
Navigate to
clear registration
and press select (
⏎
).
3.
Register your device to your RAPT account according to the instructions on page 3.
Signal Strength (dBm)
What it means
0 to -30dBm
Maximum signal
-50dBm
Excellent signal
-67dBm
Good, reliable signal
-70dBm
Ok, not a strong signal
-80dBM
Poor, unreliable signal
-90dBM
Unusable