RAPT Temperature Controller Instruction Manual
Page
13
of
17
Last Updated 24/05/2022 12:17 PM
Advanced Settings
The advanced settings should not need to be adjusted out of the box unless necessary. For more
advanced users the RAPT Temperature controller has an advanced settings menu that can be
adjusted allowing further instructions to be given to the controller such as different cooling start
delay times, tighter temperature hysteresis settings and more frequent telemetry frequencies.
To change any of the advanced settings enter the
Menu
by pressing select (
⏎
). Once in the menu
navigate to
Settings
and press select (
⏎
).
Navigate to the advanced setting you need to adjust and press select (
⏎
)
on this setting. Then use
the Up or Down arrow to adjust the set value for the setting.
Default Settings
SETTING
DEFAULT
MIN
MAX
Cooling Hysteresis Error
2.0°C
0.1°C
10.0°C
Heating Hysteresis Error
2.0°C
0.1°C
10.0°C
Compressor Delay
5.0 min
2.0 min
10.0 min
Switch Mode Delay
5.0 min
2.0 min
10.0 min
Telemetry Frequency
30 min
15 min
180 min
Set Temperature
20.0°C
-5.0°C
60.0°C
Boolean Heating On/Off
ON
OFF
ON
Boolean Cooling On/Off
ON
OFF
ON
PID Cycle Time (Heating)
120 sec
30 sec
3600 sec
PID P Coefficient (Heating)
PID I Coefficient (Cooling)
PID Cycle Time (Cooling)
120 sec
30 sec
3600 sec
PID P Coefficient (Cooling)
PID I Coefficient (Cooling)
High Temp Alarm
120°C
-20.0°C
120.0°C
Low Temp Alarm
-10°C
-20.0°C
120.0°C
NOTE: The device will alarm if the Min/Max values are exceeded.