14.3.1
Views and basic dimensions
Fig.14-8:
View and device description of the Gateway box
1
... Status and error LEDs
2
... PG gland (M20) for voltage supply, enabling
control device and emergency stop
3
... PG gland (M16) for separate
functional ground (status as
supplied with dummy plugs)
4
... Coninvers female connector for KeTop con-
nection cable
5
... PG glands (M16) for data lines
6
... PG glands (M16) for data lines (status as sup-
plied with dummy plugs)
WARNING!
Danger to persons by electric shock!
●
Only supply the device with power from voltage sources having protective
extra-low voltage (e.g. SELV or PELV acc. to IEC 61131-2)
●
Only connect voltages and circuits which are safely separated from dan-
gerous voltages (e.g. by means of sufficient insulation) to connections,
terminals or interfaces up to a rated voltage of 50 V.
Accessories
KeTop T10
© KEBA 2014
Project engineering manual V1.02
52