14.2.6
Technical data of Junction Box JB 001
General data
Rated supply voltage (KeTop):
24 V DC (rated voltage tolerance 19.2 V DC to
30 V DC according to EN 61131-2)
Power consumption:
Without KeTop: none
With KeTop: see chapter "Technical Data - In
general"l
Inrush current (KeTop):
see chapter "Technical Data - In general"
Safety class:
III in accordance with EN 61131-2 and
EN 50178
Protection degree:
IP20
Environmental conditions
Operating temperature:
5 °C to 55 °C (41 °F to 131 °F)
Storage temperature:
-25 °C to +70 °C (-13 °F to 158 °F)
Relative humidity (non-condensing):
5 % to 95 %
Vibration resistance (operation):
IEC 60068-2-6:
●
5 Hz
≤
f < 9 Hz at 7 mm
●
9 Hz
≤
f < 150 Hz at 2 g
Shock resistance (operation):
15 g / 11 ms (IEC 60068-2-27)
Mechanical properties
Construction:
Steel panel housing, blue zinc coated, with-
stands grease, oil, lubricants, alcohol, etc.
Flammability class:
UL94-V0
Dimensions:
●
Width:
67.2 mm (2.6457 in)
●
Height:
76.1 mm (2.9961 in)
●
Depth:
26 mm (1.0236 in)
Weight:
220 g (0.485 lb)
14.3 KeTop CB211 Connection Box
The KeTop CB211 connection box is used for integration of the KeTop in the
machine/system. It is suitable for wall mounting and can also be mounted on
a mounting rail through the use of the mounting rail assembly kit
(KeTop DR200).
KeTop T10
Accessories
© KEBA 2014
Project engineering manual V1.02
51