KC-P30 x-series
Functions
Configuration manual V4.14
38
© KEBA
Manufacturer
Model
Janitza
ECSEM114MID
Siemens
7KT1260
The following meters can be read out directly from the charging stations us-
ing Modbus TCP.
Manufacturer
Model
ABB
M2M
ABB
M4M
Carlo Gavazzi
EM 24
Gossen Metrawatt
EM228X
Gossen Metrawatt
EM238X
KOSTAL
Smart Energy Meter
Siemens
7KM2200
TQ Systems
EM420
TQ Systems (B-control)
EM300 LR (EM420 compatible)
TQ Systems (B-control)
EM300 LRW (EM420 compatible)
Information
Detailed information about the meter installation can be found in the instal-
lation instructions of the meter manufacturer.
5.5.3
Settings
The Modbus TCP feature is disabled by default. If an external meter with a
Modbus TCP network interface has been installed in the system, it must be
configured in the web interface in advance.
The maximum permitted charging current per phase and the maximum per-
mitted charging capacity for the entire charging network can be configured in
the web interface (under Configuration > External TCP Meter).
If the connection to the external meter gets interrupted, you can use the web
interface to configure the charging capacity at which charging is to continue.
If "0" is entered or if the field remains empty, the charging processes are in-
terrupted in the event that the connection to the external meter is interrupted.