KC-P30 x-series
Web interface
Configuration manual V4.14
23
© KEBA
●
Charging Network Parameters
●
Chargepoint Parameters
Charging Preferences
A charging profile for the charging station can be defined here.
Depending on the current occupancy of the charging station and the current
available in the entire charging network, the charging station charges ac-
cording to the set profile. If no current limit is set, the maximum available cur-
rent is used for charging.
Charging Network Settings
The nominal supply voltage of the charging station is selected here and the
current limits for the charging network can be set.
With 1- or 2-phase charging vehicles, asymmetrical loading of the 3 phases
may occur. For such vehicles, the maximum charging current can be set in
this area. The charging station then detects whether the vehicle is a 1-, 2- or
3-phase charging vehicle and, if necessary, reduces the charging current to
the set value. If "0" is entered, this function is deactivated.
You can also set whether charging should continue after a power failure.
This setting is disabled by default.
Operating Mode
Here is determined whether the charging station is operated as a single
charging station or as a master charging station in a charging network.
The number of clients must be entered for a charging network. In addition,
all attached client charging stations must be entered with their respective se-
rial numbers. Otherwise, the client charging station will not be recognized by
the master charging station in the network. The serial number is printed on
the rating plate of the client charging station.
Both the master charging station and all attached client charging stations
can be enabled ("available") or disabled ("out of service") individually. If the
charging station is disabled during a charging process, the charging process
will be stopped. When the charging station is disabled, the LED bar slowly
flashes orange and the display shows that the charging station is out of op-
eration.
Chargepoint Parameters
The connection type (1-phase or 3-phase) of the charging station is selected
here. For a 1-phase connection, the power cable wire that is used can also
be selected. For a charging network, the connection type of the client charg-
ing stations can also be selected.