KC-P30 x-series
Configuration
Configuration manual V4.14
16
© KEBA
Activation of communication - DSW2.5
Function
Figure
Activation of communication
This DIP switch setting must be made for each master and
client charging station to enable charging station communica-
tion.
Information
Changes to the DIP switch settings only become effective after a restart of
the charging station!
To restart, press the "Service button" until the first beep (approx. 1 second)
or switch off the charging station for a short time via the line circuit breaker.
3.3
Enabling the DHCP server
To simplify the setup of a charging network, the master can be configured as
a DHCP server. This function is required for the network configuration when
the master and a client are connected directly or when a network connection
is implemented via switch.
The DHCP server on the master is deactivated in the delivery state and can
be activated using the configuration via USB stick or in the web interface.
3.4
Configuration in series via USB stick
There is the option of configuring multiple P30 x-series units with the same
settings. In this process, the configuration of a P30 x-series is saved on a
USB stick and then transferred to other P30 x-series units.
Preparation
For configuration using a USB stick, the following materials are required:
●
An empty USB stick, formatted with FAT32
●
Computer
In addition, settings must be activated in the web interface (under Configura-
tion > Device) that permit the configuration to be read out and imported:
●
"Allow USB init": Enables the readout of the configuration. This setting
must be activated on the charging station which provides the configura-
tion.
●
"Allow USB config": Enables the import of the configuration. This setting
must be activated in the charging station to which the configuration is
transferred.