KC-P30 x-series
Functions
Configuration manual V4.14
31
© KEBA
Mode
Description
FirstLocal
The authorization request is first compared to the locally stored
RFID cards stored at the charging station. If the RFID card is
not stored locally and a OCPP backend is used, a comparison
takes place with the RFID cards stored at the OCPP backend.
If no OCPP backend is used, this setting must be used for an
authorization to be active.
FirstOnline
The authorization request is always compared to the RFID
cards stored on the OCPP backend. There is no comparison to
the locally stored RFID cards stored at the charging station.
OnlyLocal
The authorization request is always compared to the RFID
cards stored locally at the charging station. No comparison is
made to the RFID cards stored at the OCPP backend.
Offline authorization mode
This defines how an authorization request is handled if the connection to the
higher-level OCPP backend fails.
Mode
Description
OfflineLocalUnknown
Authorization
All RFID cards are accepted, even if they are not stored locally
at the charging station. Only those RFID cards that are stored
locally at the charging station and have a status other than "AC-
CEPTED" are rejected.
OfflineLocalAuthorization
Only RFID cards stored locally at the charging station with the
status of "ACCEPTED" are accepted.
OfflineNoAuthorization
All RFID cards are temporarily accepted. As soon as the con-
nection to the OCPP backend exists again, the RFID card is
checked and, if an invalid RFID card is being used, the charging
process is canceled.
OfflineNoCharging
Charging is not possible in case of a connection failure.
OfflineFreeCharging
In offline mode, authorization is deactivated.
5.2.2
Displays and signals
During RFID authorization, the charging station can display different light
patterns on the LED bar and emit acoustic signals.
LED bar
Display
Description
Flashing green
(every 3 seconds)
Authorization is done correctly.
Flashing blue
(every 3 seconds)
The charging station is waiting for authorization to enable a
charging process. Authorization necessary, either with RFID
card or by an external input.
Illuminated orange
(once)
The RFID card is invalid.
Acoustic signals
Signal
Description
Single tone