D3-DA 3xx/x
Technical data
Project engineering manual V1.07
92
© KEBA
12.3.1
Current data D3-DA 320/x-16xx
Information
Current data per axis in the axis module 230/400/480 V AC refers to the
supply voltage for the supply module.
The value in the following table is output current and specified for each axis
of the respective product variant (see
3.4 Overview D3-DA 3xx/x variants
At U
supply
= 230 V and 400 V
F
S
2 kHz
4 kHz
8 kHz
12 kHz
16 kHz
Nominal current:
16 A
16 A
15.4 A
10.5 A
7.7 A
Maximum current for 2 s:
32 A
32 A
29.3 A
19.9 A
14.7 A
Maximum current for 500 ms:
40 A
40 A
29.3 A
19.9 A
14.7 A
Maximum current at F
M
= 0 Hz:
36 A
29.5 A
20.2 A
13.7 A
10.1 A
At U
supply
= 480 V
F
S
2 kHz
4 kHz
8 kHz
12 kHz
16 kHz
Nominal current:
16 A
16 A
11 A
8.2 A
6.3 A
Maximum current for 2 s:
32 A
32 A
21 A
15.5 A
10.4 A
Maximum current for 500 ms:
40 A
36 A
20.9 A
15.5 A
12.4 A
Maximum current at F
M
= 0 Hz:
36 A
26 A
14.4 A
10.7 A
8.5 A
12.3.2
Current data D3-DA 310/x-18xx
Information
Current data per axis in the axis module 230/400/480 V AC refers to the
supply voltage for the supply module.
At U
supply
= 230 V and 400 V
F
S
2 kHz
4 kHz
8 kHz
12 kHz
16 kHz
Nominal current:
18 A
18 A
16 A
12.4 A
9.6 A
Maximum current for 2 s:
36 A
36 A
32 A
24.8 A
19.3 A
Maximum current for 500 ms:
48 A
48 A
32 A
24.8 A
19.3 A
Maximum current at F
M
= 0 Hz:
37.5 A
31.4 A
20.3 A
15.8 A
12.3 A
At U
supply
= 480 V
F
S
2 kHz
4 kHz
8 kHz
12 kHz
16 kHz
Nominal current:
18 A
18 A
13.2 A
9.2 A
7 A
Содержание D3-DA 3 Series
Страница 1: ...KeDrive D3 DA 3xx x Axis module Project engineering manual V 1 07 Translation of the original manual ...
Страница 4: ...D3 DA 3xx x Project engineering manual V1 07 4 KEBA ...
Страница 60: ......
Страница 107: ...D3 DA 3xx x Declaration of conformity Project engineering manual V1 07 107 KEBA ...
Страница 108: ...D3 DA 3xx x Declaration of conformity Project engineering manual V1 07 108 KEBA ...