D3-DA 3xx/x
Mounting and installation instructions
Project engineering manual V1.07
27
© KEBA
5
Mounting and installation instructions
During the installation it is imperative to avoid
●
Drill chippings, screws or foreign bodies dropping into the device
●
Moisture entering the device
WARNING!
Dangerous voltage may be applied to the device, even if the device does
not emit any visual or audible signals/indications!
WARNING!
Electric drives are dangerous:
●
Dangerously high voltages ≥ 50 V (capacitor charge) may still be present
up to 3 minutes after the power is cut. Before mounting installation and
service check that electrical power is not present at electric circuits!
●
Pay attention to warning sign on the device (see front of device).
Information
For installing the axis module within a system, also note the project manu-
als of the control module and the supply module.
Control cabinet
The module is designed only for installation in an stationary control cabinet.
The control cabinet must be conform with IP code IP44. By usage of safety
functions of the axis module or of D3-DU 3x5/x the control cabinet must be
conform with protection class IP54 or higher according to EN ISO 13849-2.
Environment
The D3-DA 3xx/x must not be installed in areas where they are exposed to
continuous vibration. (See
Pollution
Max. pollution severity 2 to EN 606641. (See
).
Adding and orientation
The modules must be mounted side by side directly without distance. Con-
necting power supply connects the modules (see chapter "Connection of
supply voltages via busbars").
Содержание D3-DA 3 Series
Страница 1: ...KeDrive D3 DA 3xx x Axis module Project engineering manual V 1 07 Translation of the original manual ...
Страница 4: ...D3 DA 3xx x Project engineering manual V1 07 4 KEBA ...
Страница 60: ......
Страница 107: ...D3 DA 3xx x Declaration of conformity Project engineering manual V1 07 107 KEBA ...
Страница 108: ...D3 DA 3xx x Declaration of conformity Project engineering manual V1 07 108 KEBA ...