D3-DA 3xx/x
Technical data
Project engineering manual V1.07
95
© KEBA
*)
The nominal current constitues 26 A for the operation in the scope of CSA /
UL.
At U
supply
= 480 V
F
S
2 kHz
4 kHz
8 kHz
12 kHz
16 kHz
Nominal current:
32 A
32 A
28.5 A
18.5A
13.7 A
Maximum current for 1.5 s:
64 A
64 A
53.3 A
39.5 A
31.6 A
Maximum current for 500 ms:
100 A
90.7 A
53.3 A
39.5 A
31.6 A
Maximum current ati F
M
= 0 Hz (for 2 s):
64 A
62.4 A
36.7 A
27.2 A
21.7 A
12.5
General safety specifications
STO
Safety category:
●
up to category 4, PL e to EN ISO
13849-1
●
up to SIL 3 to EN 62061 and EN 61508
System structure:
2-channel
PFH:
5,29 x 10
-11
for each axis, according to EN
62061 / EN 61508
DC
avg
:
High
Proof-test-interval:
20 years
Dimensioning the operating mode:
"high demand" according to EN 61508 (high
demand rate)
Reaction time:
2.5 ms
SBC
Safety category:
●
up to category 3, PL d to EN ISO
13849-1
●
up to SIL 2 to EN 62061 and EN 61508
System structure:
2-channel
PFH:
3,55 x 10
-10
for each axis, according to EN
62061 / EN 61508
DC
avg
:
Medium
Proof-test-interval:
20 years
Dimensioning the operating mode:
"high demand" according to EN 61508 (high
demand rate)
Reaction time:
3 ms
12.6
Ambient conditions
According to EN 61800-1 and the included and referenced environment clas-
sifying of standards IEC 60421-3.
Содержание D3-DA 3 Series
Страница 1: ...KeDrive D3 DA 3xx x Axis module Project engineering manual V 1 07 Translation of the original manual ...
Страница 4: ...D3 DA 3xx x Project engineering manual V1 07 4 KEBA ...
Страница 60: ......
Страница 107: ...D3 DA 3xx x Declaration of conformity Project engineering manual V1 07 107 KEBA ...
Страница 108: ...D3 DA 3xx x Declaration of conformity Project engineering manual V1 07 108 KEBA ...