49
Special adjustments
No.
Name
r/w Enter based on
CP.33
operating mode
yes
yes
Pn.19
This parameter determines the master or slave of regenerative units at parallel connection.
Further it is adjusted whether a harmonic filter or a commutation choke is series-connected.
Single units must be adjusted to master.
Value range
Meaning
0
Master with commutation reactor
1
Master with harmonic filter
2
Slave with commutation reactor
3
Slave with harmonic filter
4
Master-Slave with commutation reactor input selection
5
Master-Slave with harmonic filter input selection
No.
Name
r/w Enter based on
CP.34
regeneration level
yes
–
cS.02
Value range
Meaning
100…120 %
The regeneration level determines the starting value to energy regen-
eration. The adjusted value refers to the reference value of the DC
voltage in percentage. The status changes from Standby „Stb“ to re-
generation „rEGEn“.