48
Special adjustments
No.
Name
r/w
Enter
based on
CP.21
last error
–
–
In.24 set 0
CP.22
last error -1
–
–
In.24 set 1
CP.23
last error -2
–
–
In.24 set 2
CP.24
last error -3
–
–
In.24 set 3
CP.25
last error -4
–
–
In.24 set 4
CP.26
last error -5
–
–
In.24 set 5
CP.27
last error -6
–
–
In.24 set 6
CP.28
last error -7
–
–
In.24 set 7
Parameters CP.21…CP.28 display the last eight errors. With exception error "undervoltage
E.UP" is not stored. The oldest error is displayed in CP.28. A new error is stored in CP.21.
All other errors are shifted to the next parameter. The oldest error (CP.28) is not applicable.
The meaning of the error messages is described in parameter CP.01.
No.
Name
r/w Enter based on
CP.29
software version
–
–
In.06
Value range
Meaning
0.00…9.99
Display of the inverter software version number (e.g. 1,11).
No.
Name
r/w Enter based on
CP.30
software date
–
–
In.07
Value range
Meaning
0…6553.5
Display of the inverter software date in the format „ddmm.y“.
No.
Name
r/w Enter based on
CP.31
power unit code
–
–
Sy.03
The COMBIVERT R6-N detects the connected supply system (230 V/400 V) at the first
switching on. Depending on the supply system the COMBIVERT R6-S adjusts internally
certain parameter values.
If the COMBIVERT R6-N is connected to another supply system, these stored parameter
values are not valid any longer. Error message "power unit changed (E.Puch)" is displayed.
Value range
Meaning
0…32767
If the displayed value is written, only the power unit dependent param-
eters are re-initialised.
No.
Name
r/w Enter based on
CP.32
puls off level
yes
–
cS.06
Value range
Standard Meaning
0.0…-1000.0 kW
-0.8 kW
If the adjusted regenerative power is decreased, the COM-
BIVERT R6-N switches the modulation off after turn-off de-
lay and changes into standby mode (display: „Stb“).