20
Technical Data
3.4
Operating conditions
Standard
Class
Instructions
Definition acc.
EN 61800-2
Inverter-product standard:
Rated specifications
EN 61800-5-1
Inverter-product standard:
General safety
Site altitude
max. 2000 m above sea level
With site altitudes over 1000 m a derating of 1 %
per 100 m must be taken into consideration.
Ambient conditions during operation
Climate Temperature EN 60721-3-3
3K3
extended to -10…45 °C
(with temperature over 45°C to max. 55°C
a derating of 5 % per 1 K must be taken into
consideration)
Humidity
3K3
5…85 % (without condensation)
Mechanical
Vibration
Track
EN50155
max. amplitude of a vibration 1 mm
(5…13 Hz)
max. acceleration amplitude 7 m/s²
(13…200 Hz)
Germ. Lloyd
Part 7-3
EN 60721-3-3
3M4
Contamination
Gas
3C2
Solids
3S2
Ambient conditions during transport
Climate
Tempera-
ture
EN 60721-3-2
2K3
Humidity
2K3
(without condensation)
Mechanical
Vibration
2M1
max. vibration amplitude 3.5 mm
(2…9 Hz)
max. acceleration amplitude 15 m/s²
(9…200 Hz)
Surge
2M1
max. 100 m/s²; 11 ms
Contamination
Gas
2C2
Solids
2S2
Ambient conditions for the storage
Climate
Tempera-
ture
EN 60721-3-1
1K4
Humidity
1K3
(without condensation)
Mechanical
Vibration
1M1
max. amplitude of a vibration 1 mm
(5…13 Hz)
max. acceleration amplitude 7 m/s²
(13…200 Hz)
Surge
1M1
max. 100 m/s²; 11 ms
Contamination
Gas
1C2
Solids
1S2
Type of protection
EN 60529
IP20
Environment
IEC 664-1
Pollution degree 2
Definition acc.
EN 61800-3
Inverter-product standard:
EMC
EMC emitted interference
Cable-based interferences
–
C2
with EMC filter and ferrite rings
Radiated interferences
–
EN 61800-3
with EMC filter and ferrite rings
Interference immunity
Static discharges
EN 61000-4-2
8 kV
AD (air discharge) and CD (contact dis-
charge)
continued on the next page