40
Connection of the control board version N
4.5.3 Wiring example
Attention
EMC
In order to prevent a malfunction caused by interference voltage supply on the control in-
puts, the following directions should be observed:
• Use shielded/drilled cables
• Lay shield on one side of the inverter onto earth potential
• Lay control and power cable separately (about 10...20 cm apart); lay crossings in a right
angle
max. 25 mA DC
per digital output
Analog output
0…±10 V DC / 5 mA
max. 30 V DC
0.01…2 A
max. 30 V DC
0.01…2 A
Power supply of the inverter
inputs
Control release inverter
U
X2A
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
Figure 21: Wiring example R6-N
internal
Connection external
Содержание Combivert R6