background image

IF NOT INSTALLED, OPERATED AND MAINTAINED

IN ACCORDANCE WITH THE MANUFACTURER’S

INSTRUCTIONS, THIS PRODUCT COULD EXPOSE

YOU TO SUBSTANCES IN FUEL OR IN FUEL

COMBUSTION WHICH CAN CAUSE DEATH OR

SERIOUS ILLNESS AND WHICH ARE KNOWN TO

THE STATE OF CALIFORNIA TO CAUSE CANCER,

BIRTH DEFECTS OR OTHER REPRODUCTIVE

HARM.

II INSTALLATION

This Pasta System MUST be

installed, inspected, calibrated and

serviced by qualified and/or certified

and/or licensed service personnel –

you may void your Keating warranty

if installation is not completed per

current local, national and Keating

specifications. Contact your dealer

for assistance.

DAMAGE DURING 

SHIPMENT

The Pasta System has been assembled, tested and

inspected at the factory. Upon arrival, the complete

Pasta System should be checked for any damage that

may have occurred during shipment.
The carrier is responsible for all damage in transit

whether visible or concealed. Do not pay for the freight

bill until the Pasta System has been thoroughly checked

for damage. If concealed damage is found later, contact

the carrier immediately to file a claim.

What to do if equipment arrives damaged:

VISIBLE LOSS OR DAMAGE — Be certain to note this

on the freight or express receipt and have it signed by

the delivery person.
FILE CLAIM FOR DAMAGES  IMMEDIATELY —

Regardless of extent of damage.

CONCEALED LOSS OR DAMAGE — If damage is

noticed when equipment is unpacked, notify the freight

company immediately, and file a “concealed damage

claim”. This MUST be done immediately. Be sure to

retain the shipping container for inspection.
Keating does not assume responsibility for Loss OR

Damage incurred in transit.

¥

¥

NOTE:

Interstate commerce regulations require that

the claim must be initiated by the consignee within 10

days from the date it is received.

INSTALLATION

Installation must conform with local codes or, in

absence of local codes, with the current National Fuel

Gas Code Z223.1/NFPA 54, Natural Gas Installation

CAN/CGA - B149.1 or Propane Installation Code

CAN/CGA-B149.2. 

POSITIONING

The pasta cooker must be no closer than 6" from any

combustible material. When placed under an exhaust

hood with a fire retardant system it must comply with

ANSI/UL 507-(Latest Edition) and ANSI/NFPA 96-

(Latest Edition). No frame or restriction can be

constructed around the lower part of the pasta cooker

that would restrict ventilation or air movement into the

pasta cooker. You must insure adequate air supply to

the pasta cooker. 

ALL

connections and placement must

comply with local and national codes. It is the

responsibility of the owner and local installer to comply

with these regulations when installing the Pasta

System.
Adequate clearance for servicing and proper operation

must be maintained. Your pasta cooker is designed to

be serviced from the front. Do not place a pasta cooker

next to a deep fat fryer. Hot oil and water can cause an

unstable condition creating a hazardous situation. The

pasta cooker will operate at highest efficiency when

properly leveled. Place a level across the cooker front

panel from left to right, and then front to rear. Screw the

adjustable bullet feet or casters in or out as necessary

until the cooker is as level as possible. Each leg is

adjustable to 

3

/

4

". Do not expose more than three

threads on the stem of the caster.
Counter model and floor model Pasta System cookers

must be restrained to prevent tipping

when installed

in order to avoid splashing, spilling, etc. of hot liquid.

The restraining method may be a manner of installation

or by separate means.

LEVELING

The Pasta System will operate at its highest efficiency

when properly leveled. Place a level on Pasta System

vessel from side to side. For Pasta Systems on legs, the

bottom foot of the leg is adjustable.  Turn counter

clockwise to increase height or clockwise to decrease

height until level. For Pasta Systems on casters, the

casters are adjustable by loosening the jam nut and

turning the caster in or out. When the desired level is

reached, tighten the jam nut. Adjustments of more than

3/4” are not recommended on any caster.  The same

procedure should be followed to level the Pasta System

from front to back. 

CLEARANCES

Combustible

Construction

Non-Combustible

Construction

Back

6"

0"

Right Side

6"

0"

Left Side

6"

0"

WARNING

Improper installation
can cause damage,
injury or death.

WARNING

3

Содержание Custom Pasta Gas System 0107

Страница 1: ...NEW PERSONNEL 1 800 KEATING www keatingofchicago com ON OFF 100 220 OFF 200 12 0 140 160 18 0 100 220 OFF 200 12 0 140 160 18 0 PILOT TO LITE 30 SEC HOLD MUST BE ON FOR PILOT OFF ON MAIN POWER T3 T2...

Страница 2: ...right to change specifications at any time NOTICE NOTICE IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUT OFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SER...

Страница 3: ...6 SECTION III OPERATING THE PASTA SYSTEM Filling 6 Lighting 6 Indicating Lights 7 Cooking 7 Shutdown 7 Draining 7 8 Cleaning 8 Electronic Timers 8 9 SECTION IV MAINTENANCE Warranty Repairs 9 Preventiv...

Страница 4: ...r when the timer button is pressed and raises the baskets when the cooking cycle is complete Split baskets are required for these models SAFETY PRECAUTIONS THIS SYMBOL WARNS YOU THAT SERIOUS BURNS OR...

Страница 5: ...entrations that would pose a significant risk to the consumer when the equipment is installed operated and maintained as follows l Installed in accordance with all local codes or in the absence of loc...

Страница 6: ...han 6 from any combustible material When placed under an exhaust hood with a fire retardant system it must comply with ANSI UL 507 Latest Edition and ANSI NFPA 96 Latest Edition No frame or restrictio...

Страница 7: ...ST BE USED n n BEFORE OPERATING THIS PASTA SYSTEM CHECK PIPE JOINTS FOR LEAKS BY USING A SOAP AND WATER SOLUTION OR SNIFFER ONLY DO NOT USE AN OPEN FLAME Figure 2 3 Main Gas and Water Supply Connectio...

Страница 8: ...cessary if your Pasta System has an optional spark ignitor NOTE It is estimated that half of all service calls made on Keating Pasta Gas Systems result from an inadequate gas supply During installatio...

Страница 9: ...hose must be used to avoid leaking when the Pasta System is moved for cleaning If during operation the boil is killed when water automatically enters the Pasta System turn the water pressure down unt...

Страница 10: ...WHO HAVE BEEN THOROUGHLY TRAINED IN OPERATING PROCEDURES n n USE ONLY KEATING APPROVED BASKETS IN YOUR PASTA SYSTEM NEVER OVERFILL BASKETS DO NOT BANG BASKETS ON BASKET HANGERS OR PASTA SYSTEM VESSEL...

Страница 11: ...OIL OUT TRAINED PERSONNEL MUST BE PRESENT DURING THE PROCEDURE TO PREVENT BOIL OVER OR TO TURN OFF THE POWER IF WATER DROPS BELOW HEAT TRANSFER TUBES 5 Turn Pasta System on and bring water and a gentl...

Страница 12: ...mately two seconds The display will show SEt Press the button for the channel to be programmed The display will show the current setting for that channel Use the up or down button to increment or decr...

Страница 13: ...than 15 F 9 44 C off simply loosen three dial plate retaining screws rotate dial plate to match thermometer reading and tighten screws If the thermostat is more than 15 F 9 44 C off then a qualified s...

Страница 14: ...THE OFF POSITION AND CLEAN THE SENSORS THOROUGHLY IF THE PROBLEM STILL OCCURS HAVE THE WATER AUTO FILL SYSTEM CHECKED BY A QUALIFIED SERVICE TECHNICIAN Figure 4 3 Sensor Tube Location V SERVICE DIAGNO...

Страница 15: ...irty runner pilot tube or pilot c Low pilot flame height d Flame switch is faulty e Momentary switch is faulty f Exhaust problems or drafts in kitchen g Delayed ignition a Verify if size of incoming g...

Страница 16: ...System to proper level b Check low water safety shut off system Custom Pasta System vessel boiling over or excessive starch overflow a Product overloaded in Custom Pasta System vessel b Excessive amou...

Страница 17: ...place flame switch Part 004311 Timers counting down in the wrong mode Not minutes and seconds a Reset the timer see instructions on page 9 Water leaking in the rear of the Custom Pasta System a Replac...

Страница 18: ...onnect wires from the board 3 Unscrew mounting screws There are three of them per board 4 Replace the board 5 Reconnect the wires 6 Adjust sensitivity 7 Close the box 8 Seal the box using silicone and...

Страница 19: ...cated inside of the door The model and serial numbers are necessary when ordering ITEM DESCRIPTION QUANTITY PART NUMBER 1 THERMOSTAT 2 031466 2 DIGITAL TIMER S 2 056921 3 TOGGLE SWITCH 1 004501 4 INDI...

Страница 20: ...G LIGHT GREEN SECONDARY BURNER ON 1 009375 5 UNUSED 3 6 DIGITAL TIMER S 2 056921 7 THERMOSTAT 2 031466 8 DIAL PLATE 2 034975 9 THERMOSTAT KNOB 2 004163 10 FLAME SWITCH NOT SHOWN 1 037406 11 LOW WATER...

Страница 21: ...10 RUNNER PILOT ORIFICE HOLDER STRAIGHT 004142 1 1 2 11 RUNNER PILOT 90 ELBOW 1 4 1 8 015746 1 2 2 2 12 RUNNER PILOT 90 ORIFICE HOLDER CM 005742 1 13 RUNNER PILOT SOLENOID ADAPTER 005743 2 1 1 1 RUNNE...

Страница 22: ...016346 1 1 1 29 HI LIMIT CONTROL W RESET ALL 034357 1 1 1 1 30 THERMOSTAT ALL SEE PAGE 18 31 SECONDARY THERMOSTAT ALL SEE PAGE 18 32 BASKET HANGER MOUNTING BLOCK ALL LEFT 004539 1 1 1 1 CENTER 003813...

Страница 23: ...20 PASTA SYSTEM WIRING DIAGRAM...

Страница 24: ...21 GAS PASTA SYSTEM WITH BASKET LIFT WIRING DIAGRAM...

Страница 25: ...PARTICULAR PURPOSE OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from...

Страница 26: ...SERIAL NUMBER ______________________________ q FRYER q FILTER SYSTEM q GRIDDLE REMARKS ____________________________________ q TOP SIDE COOKER q HOT PLATE q PASTA PLUS I HAVE READ THE INSTALLATION AND...