DISCLAIMER OF WARRANTY AND LIMITATION OF REMEDY

KCI HEREBY DISCLAIMS ALL EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION ANY IMPLIED 
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ON THE KCI PRODUCT(S) DESCRIBED 
IN THIS PUBLICATION EXCEPT FOR THE WRITTEN LIMITED WARRANTY INCLUDED WITH THIS PRODUCT.  UNDER 
NO CIRCUMSTANCES SHALL KCI BE LIABLE FOR ANY INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES AND 
EXPENSES, INCLUDING DAMAGES OR INJURY TO PERSON OR PROPERTY, DUE IN WHOLE OR IN PART TO THE USE OF 
THE PRODUCT OTHER THAN THOSE FOR WHICH DISCLAIMER OF WARRANTY OR LIMITATION OF LIABILITY IS EXPRESSLY 
PROHIBITED BY SPECIFIC, APPLICABLE LAW.  NO PERSON HAS THE AUTHORITY TO BIND KCI TO ANY REPRESENTATION 
OR WARRANTY EXCEPT AS SPECIFICALLY SET FORTH IN THIS PARAGRAPH.

Descriptions or specifications in KCI printed matter, including this publication, are meant solely to generally describe the 
product at the time of manufacture and do not constitute any express warranties except as set forth in the written limited 
warranty included with this product.  Information in this publication may be subject to change at any time.  Contact KCI 
(see page 28) for updates.

Important Information For Users

This manual contains routine service procedures for the ActiV.A.C.

®

 Therapy Unit sold by KCI.  This manual is not intended 

for repair or non-routine service procedures.  Contact KCI (see page 28) for any repair or non-routine service not covered 
by this manual.

Please read and understand all sections of this manual before beginning any service procedures on this equipment. 

In order for KCI products to perform properly, KCI recommends the following.  Failure to comply with these conditions will 
void any applicable warranties.
•  Assembly, operations, extensions, re-adjustments, modifications, service or repairs must be performed by qualified 

personnel authorized by KCI.

•  Access codes to engineering screens are proprietary and remain property of KCI, and may only be used for the limited 

purpose as outlined in KCI copyrighted documentation.

•  The electrical installation of the room must comply with the appropriate national electrical wiring standards.
•  Use this product only in accordance with its user manual and applicable product labeling.
•  Ensure that personnel performing the procedures detailed in this manual are properly trained and qualified to perform 

service on medical devices.

•  Follow all procedures as outlined in this manual, including infection prevention and control and care and cleaning.
•  Document and retain as a permanent record all service procedures performed.
•  Use only KCI V.A.C.

®

 Dressings and accessories with this product.

Notice

This product has been configured from the manufacturer to meet specific voltage requirements.  Refer to the Product 
Information Label for specific voltage.

Indications, contraindications, warnings, precautions and other safety information are contained in the V.A.C.

®

 

Therapy System Safety Information Sheet.  This information sheet is included with the ActiV.A.C.

®

 Therapy Unit 

and also included in every V.A.C.

®

 Dressing carton.  Please consult the ActiV.A.C.

®

 Therapy Unit User Manual and 

Safety Information Sheet before applying V.A.C.

®

 Therapy.  If there are questions or these documents are missing, 

immediately contact your local KCI representative.

Содержание ActiV.A.C.

Страница 1: ...ActiV A C Therapy Unit Owner Service Manual 418474 Rev A February 2018 Important Document File in your maintenance records...

Страница 2: ......

Страница 3: ...sure Checks 13 Set up 13 25 mmHg Test 14 125 mmHg Test 14 200 mmHg Test 15 125 mmHg Test 16 Charge Battery and 6 Hour Unit Verification Test 17 Verify Time and Date 20 Alarm Tests 20 Leak Alarm 20 Blo...

Страница 4: ...any service procedures on this equipment In order for KCI products to perform properly KCI recommends the following Failure to comply with these conditions will void any applicable warranties Assembly...

Страница 5: ...Unit for use includes unpacking inspection for any damaged or missing parts and an initial round of service procedures to ensure the battery is fully charged and the unit is ready for patient use The...

Страница 6: ...tton Battery Charging Indicator LED USB Data Port Manufacturer Service Port Tripping Hazard No bathing or showering Tripping Hazard No bathing or showering Mains Power Cord Power Supply Power Cord War...

Страница 7: ...l protective equipment PPE and hand hygiene protocols in accordance with the following standards 29 CFR 1910 1030 OSHA Bloodborne Pathogens Standard MMWR October 2002 51 No RR 16 Guidelines for Hand H...

Страница 8: ...otocols Moisten a cotton tipped applicator with antiseptic thoroughly wipe the interior of the filter compartment The Exhaust Filter is single use only 5 Wipe down the back of the unit with antiseptic...

Страница 9: ...unplugged from the therapy unit and or any power source 2 Wipe the power supply and cord with antiseptic Allow to air dry 3 Inspect the power supply brick cords and connectors for damage and cracked...

Страница 10: ...C Canister KCI P N M8275058 two 2 each These are normal ActiV A C canisters that can be reused for up to 6 months as a test canister KCI recommends marking the canister with Test Canister Not For Huma...

Страница 11: ...t filter This procedure can be skipped if the unit is new and has not been previously placed with a patient 1 Insert a new exhaust filter 2 Ensure the filter is fully seated 3 With the Exhaust Filter...

Страница 12: ...n external computer The ActiV A C unit exports a file folder that uses the unit serial number as its name The folder contains a Comma Separated Values CSV file named by date YYYYMMDD csv 14 For the in...

Страница 13: ...battery 1 Verify that the Battery Change Due date on the Battery History label is at or exceeds the current date 2 Remove the Battery History Label 3 Using a 1 Phillips screwdriver remove the two 4 40...

Страница 14: ...using ensuring the wiring harness is on the front side of the battery and NOT behind and is otherwise not tangled or obstructing fitting the battery fully into the battery compartment 14 Press the Pow...

Страница 15: ...e Valve Hygroscopic Filter connected to Pump Port Power On Off Switch Hygroscopic Filter connected to Pump Port 4 Ensure the tubing with the hygroscopic filter is connected to the pump port and the pl...

Страница 16: ...Pressure Exit _ 25 mmHG 7 Press OK 8 Start therapy by pressing On Off the Therapy Start screen will appear Continuous Therapy Off 0 mmHg Confirm OK Back Pressure 25 mmHg Mode Continuous Intensity Low...

Страница 17: ...l manometer and the displayed pressure on the ActiV A C Touch Screen 10 The digital manometer should stabilize and indicate the pressure displayed touch screen 10 mmHg 11 Press Exit one 1 time 12 Pres...

Страница 18: ...Hg Pressure Exit _ 125 mmHG 3 On the Confirm screen ensure that settings are Pressure 125 mmHg Mode Continuous Intensity Low 4 Press OK 5 Observe the digital manometer and the displayed pressure on th...

Страница 19: ...ll socket 5 Verify the Battery Charging Indicator LED is lit Battery charging in process Battery charging complete An amber light means the battery is charging A green light means the battery is fully...

Страница 20: ...ge 28 Continuous Therapy Off 0 mmHg Pressure Exit _ 125 mmHG Continuous Therapy Off 0 mmHg Confirm OK Back Pressure 125 mmHg Mode Continuous Intensity Low Clinician Mode 6 Aug 2009 15 06 12 Attach a r...

Страница 21: ...ime period is achieved 26 Press On Off to stop therapy 27 At the end of the six hour verification period carefully check the unit for Control buttons not responding Excessively hot unit No alarms are...

Страница 22: ...4 Set the correct date and time 5 Press Exit two times to return to the Clinician Home Screen Exit Set Time Date Year Minute Hour 24 Day Month _ _ _ _ _ Alarm Tests The purpose of these tests is to e...

Страница 23: ...n press On Off 4 From the Therapy Start screen press Exit to return to the Clinician Home screen 5 The Blockage Alert should activate in approximately two minutes or less 6 Press Exit to return to the...

Страница 24: ...er Not Engaged alarm should sound in approximately thirty 30 seconds or less 9 Ensure that the alarm sounds with three 3 beeps 10 Press Reset to return to the Clinician Home Screen 11 Continue on to C...

Страница 25: ...e ActiV A C Therapy Unit still powered off set the unit in a secure place where it can be left for a minimum of six hours 2 Plug the power supply cord into the ActiV A C unit 3 Plug the mains power co...

Страница 26: ...try appropriate mains power cord Preparation For Use 1 Carefully wrap the power cords into a bundle and place the power supply into a clear plastic bag 2 Position the ActiV A C Therapy Unit in the fab...

Страница 27: ...the fabric carrying case flap to provide additional accidental impact protection to the Touch Screen when the flap is properly closed 2 Insert the ActiV A C Therapy Unit Quick Reference Guide and V A...

Страница 28: ...y Voltage Input 100 240 VAC Frequency 50 60Hz Amperage 0 72A 115VAC External Power Supply Output 12V 3 3 A Patient Enclosure Leakage Current 100 Microamps Battery Information Type Lithium ion Li ion P...

Страница 29: ...ning Label 2 required 340168 ActiV A C Battery History Label 340171 ActiV A C Logo Label 340225 ActiV A C North American Mains Power Cord 340226 ActiV A C Power Supply 340367 ActiV A C Compliance Labe...

Страница 30: ...cal and Electronic Equipment Directive 2002 96 EC At the end of useful life dispose of all waste according to local requirements or contact your local KCI subsidiary or agent for advice Not protected...

Страница 31: ...ention and Control process pg 5 Inspect Unit For Damage pg 8 Blockage Alert pg 21 Canister Full Therapy Interrupted pg 22 Recharge Battery pg 23 Contact KCI see page 28 Fail Fail Fail Fail Fail Fail F...

Страница 32: ...Manufactured for KCI USA Inc 12930 IH10 West San Antonio Texas 78249 USA www acelity com...

Отзывы: