INFORMATION MESSAGES
No.
Info. message
Description
Remedy
203
Fill level aquaCool canister
low
The content of the aquaCool canister is
sufficient for another 2.5 hours of oper-
ation with a spraying time of 6 seconds
each.
Replace the empty aquaCool canister with a full
one. Do not replace aquaCool with any other liquid.
204
Connection aquaCool unit
faulty
Communication between control and
module / interior control panel has
been interrupted.
Check / replace the patch cable. Acknowledge the
message by pressing START. If the fault persists,
contact your customer service.
205
Connection audio module
faulty
206
Connection inside display
faulty
207 aquaCool canister empty
aquaCool canister empty.
Replace the aquaCool canister with a full one.
See chapter: Refilling Aroma and aquacool.
208
Aroma supply low, please
renew
System has run out of scent.
Replace the Aroma tin.
See chapter: Refilling Aroma and aquacool.
210
Low battery charge, please
renew
Button cell (CR-2032) of the control
board discharged.
Replace the button cell (CR-2032).
212
Connection RGB module
faulty
Communication between control and
bus module has been interrupted.
Check / replace the patch cable. Acknowledge the
message by pressing START. If the fault persists,
contact your customer service.
213 SD card missing
No SD card in the audio module.
Insert an original SD card.
See chapter: Recording to an SD card/Removing
the SD card.
214 SD card unreadable
SD card defective, incompatible
content.
Insert a new original SD card. Acknowledge the
message by pressing START. See chapter:
Recording to an SD card/Removing the SD card.
If the fault persists, contact your customer service.
216
Error voltage supply,
please check
Power supply to the mainboard varies Check power supply to the mainboard.
217
No voice files on the SD
card, pleas check.
No voice files on the SD card found.
Rebuild voice folder on the SD card. If necessary
replace original SD card.
218
Connection DALI-unit
faulty.
DALI-unit - CAN-BUS connection
lost.
Contact your customer service.
220 OW to many sensors
General OneWire sensor error.
Contact your customer service.
221 OW sensor Typ B missing
222 OW sensor Typ S missing
223 OW sensor read error
224
Check tubes and tempera-
ture sensor in the door
Temperature difference to high -
between the one wire sensors.
Check tubes and thermal sensors in the door.
Contact your customer service.
228
Check tubes and tempera-
ture sensor in the door
Minimum temperature is not reached or
is fallen below in operation mode.
Check tubes and thermal sensors in the door.
Contact your customer service.
229
Pleas close the door, check
exhaust air
Temperature rise of 1,5 degrees in 18
seconds.
Close door. Check exhaust air.
230
Connection Bluetooth
module faulty
Communication between control
and bluetooth module has been
interrupted.
Check / replace the patch cable. Acknowledge the
message by pressing START. If the fault persists,
contact your customer service.
231
No display
Internal notification - stored in the er-
ror log (service technician informa-
tion).
-
Содержание Tower pureENERGY 5.0
Страница 1: ...OPERATING INSTRUCTIONS TANNING DEVICE ...
Страница 2: ......
Страница 51: ...O p e r a t i n g I n s t r u c t i o n s KBL Tower pureEnergy 5 0 51 Remarks ...
Страница 52: ...O p e r a t i n g I n s t r u c t i o n s KBL Tower pureEnergy 5 0 52 Remarks ...
Страница 53: ...O p e r a t i n g I n s t r u c t i o n s KBL Tower pureEnergy 5 0 53 Remarks ...
Страница 54: ...O p e r a t i n g I n s t r u c t i o n s KBL Tower pureEnergy 5 0 54 Remarks ...
Страница 55: ......
Страница 56: ...Ringstraße 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 ...