19
10.2 Notes For Maintenance & Repair
10.2.1 Top panel remove
Junction box
M4 screw*2
Unscrew these 2
screws before
remove the top
panel
10.2.2 Titanium heat exchanger replace
The titanium heat exchanger’s remove and installation
can only by loosening the copper tube at the top (use
welding torch).
WARNING
Do not repair or replace heat exchangers by
unscrewing nuts. This operation will damage the
sealing surface of the nut and cause refrigerant
leakage.