05
2 GENERAL INTRODUCTION
• These units are used for both heating and cooling the water of swimming pool, they can keep the pool water temperature stable
at the set temperature to provide comfortable swimming condition in different seasons.
• A wired controller is supplied with the unit.
NOTE
• Maximum length of communication wirings between the unit and the controller is 20m.
• Power cords and communication wires must be laid out separately, they can not be placed in the same conduit. Otherwise,
it may lead to electromagnetic interference. Power cords and communication wires should not come in contact with the
refrigerant pipe so as to prevent the high temperature pipe from damaging wires.
• Communication wires must use shielded lines.
Operation range
Heating mode operation range
Cooling mode operation range
Ambient temperature °C
W
ater inlet
Temperature °C
W
ater inlet
Temperature °C
Ambient temperature °C
Water pressure range: 0.01~0.5MPa
3 ACCESSORIES SUPPLIED WITH THE UNIT
Name
Shape
Quantity
Installation & owner’s manual (this
book)
1
Installation & owner’s manual
Wired controller
1
Loose joint
2
Drain connection
1
Wired controller
1
16-20kW model can customize this area