DANGER

•  Before touching electric terminal parts, turn off power switch.
•  When service panels are removed, live parts can be easily touched by accident.
•  Never leave the unit unattended during installation or servicing when the service panel is removed.
•  Do not touch water pipes during and immediately after operation as the pipes may be hot and could burn your hands. 

To avoid injury, give the piping time to return to normal temperature or be sure to wear protective gloves.

•  Do not touch any switch with wet fingers. Touching a switch with wet fingers can cause electrical shock.
•  Before touching electrical parts, turn off all applicable power to the unit.

WARNING

•  Tear apart and throw away plastic packaging bags so that children will not play with them.Children playing with plastic 

bags face danger of suffocation.

•  Safely dispose of packing materials such as nails and other metal or wood parts that could cause injuries.
•  Ask your dealer or qualified personnel to perform installation work in accordance with this manual. Do not install the 

unit yourself. Improper installation could result in water leakage, electric shocks or fire.

•  Be sure to use only specified accessories and parts for installation work. Failure to use specified parts may result in 

water leakage, electric shocks, fire, or the unit falling from its mount.

•  Install the unit on a foundation that can withstand its weight. Insufficient physical strength may cause the equipment to 

fall and possible injury.

•  Perform specified installation work with full consideration of strong wind, hurricanes, or earthquakes. Improper 

installation work may result in accidents due to equipment falling.

•  Make certain that all electrical work is carried out by qualified personnel according to the local laws and regulations 

and this manual using a separate circuit. Insufficient capacity of the power supply circuit or improper electrical 

construction may lead to electric shocks or fire.

•  Be sure to install a ground fault circuit interrupter according to local laws and regulations. Failure to install a ground 

fault circuit interrupter may cause electric shocks and fire.

•  Make sure all wiring is secure. Use the specified wires and ensure that terminal connections or wires are protected 

from water and other adverse external forces. Incomplete connection or affixing may cause a fire.

•  When wiring the power supply, form the wires so that the front panel can be securely fastened. If the front panel is not 

in place there could be overheating of the terminals, electric shocks or fire.

•  After completing the installation work, check to make sure that there is no refrigerant leakage.
•  Never directly touch any leaking refrigerant as it could cause severe frostbite.Do not touch the refrigerant pipes 

during and immediately after operation as the refrigerant pipes may be hot or cold, depending on the condition of the 

refrigerant flowing through the refrigerant piping, compressor and other refrigerant cycle parts. Burns or frostbite are 

possible if you touch the refrigerant pipes. To avoid injury, give the pipes time to return to normal temperature or, if you 

must touch them,be sure to wear protective gloves.

•  Do not touch the internal parts (pump, backup heater, etc.) during and immediately after operation. Touching the 

internal parts can cause burns. To avoid injury, give the internal parts time to return to normal temperature or, if you 

must touch them, be sure to wear protective gloves.

CAUTION

•  Ground the unit.
•  Grounding resistance should be according to local laws and regulations.
•  Do not connect the ground wire to gas or water pipes, lightning conductors or telephone ground wires.
•  Incomplete grounding may cause electric shocks.

- Gas pipes : Fire or an explosion might occur if the gas leaks.
- Water pipes : Hard vinyl tubes are not effective grounds.
- Lightning conductors or telephone ground wires : Electrical threshold may rise abnormally if struck by a lightning bolt.

•  Install the power wire at least 3 feet (1 meter) away from televisions or radios to prevent interference or noise. 

(Depending on the radio waves, a distance of 3 feet (1 meter) may not be sufficient to eliminate the noise.)

•  Do not wash the unit. This may cause electric shocks or fire. The appliance must be installed in accordance with 

national wiring regulations..

Содержание KSWP-70 DR8

Страница 1: ...h for purchasing our product Before using your unit please read this manual carefully and keep it for future reference Swimming pool heat pump INSTALLATION OWNER S MANUAL KSWP 70 DR8 KSWP 90 DR8 KSWP...

Страница 2: ...ssibly resulting in fire electrical shock property damage or personal injury Please drain water when the unit is not in use in winter to avoid freeze damage CONTENTS 1 SAFETY PRECAUTIONS 02 2 GENERAL...

Страница 3: ...START UP AND CONFIGURATION 8 1 Initial Start up At Low Outdoor Ambient Temperature 17 8 2 Pre operation Checks 17 8 3 Failure Diagnosis At First Installation 17 9 FINAL CHECKS AND TEST RUN 18 10 MAIN...

Страница 4: ...01 NOTE The pictures in this manual are for reference only please refer to the actual product...

Страница 5: ...8 only WARNING Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the...

Страница 6: ...ure to install a ground fault circuit interrupter may cause electric shocks and fire Make sure all wiring is secure Use the specified wires and ensure that terminal connections or wires are protected...

Страница 7: ...e collection facilities Contact your local goverment for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substance can l...

Страница 8: ...wise it may lead to electromagnetic interference Power cords and communication wires should not come in contact with the refrigerant pipe so as to prevent the high temperature pipe from damaging wires...

Страница 9: ...hin the allowable ranges x Places where water leaking from the unit cannot cause damage to the location e g in case of a blocked drain pipe x Places where rain can be avoided as much as possible x Do...

Страница 10: ...te where the suction side may be exposed directly to wind To prevent exposure to wind install a baffle plate on the air discharge side of the unit In heavy snowfall areas it is very important to selec...

Страница 11: ...Check the strength and levelness of the installation floor ensure that the vibration and noise of the unit are minimized Bolts nuts gaskets shock pads foundations are not provided please purchase or c...

Страница 12: ...M8 4 Nut M8 4 Gasket M8 4 Solid foundation W H L 100 100 500 2 20 25 1 2 3 4 30 5 3 Drain Hole Position 31mm Drain hole Drain hole Connect to drain hose Drain connection For collecting the condensed...

Страница 13: ...stallation owner s manual of Wired controller 1 phase FUSE LPS NOTE The ground fault circuit interrupter must be 1 high speed type of 30mA 0 1s Stated values are maximum values see electrical data for...

Страница 14: ...units maximum allowable voltage range variation between phases is 2 3 Select circuit breaker that having a contact separation in all poles not less than 3 mm providing full disconnection where MFA is...

Страница 15: ...the first time 1 Open valve and charge water 2 Make sure that the pump and the water inlet pipe have been filled with water 3 Close the valve and start the unit Attention It is necessary that the wate...

Страница 16: ...5 Low pressure switch 15 Gas refrigerant temperature sensor 6 4 way valve 16 Liquid refrigerant temperature sensor 7 Fin coil heat exchanger 17 Water outlet temperature sensor 8 Ambient temperature se...

Страница 17: ...sembly unit Code Assembly unit 1 Compressor connection port U 5 Port for communication with main control board CN10 2 Compressor connection port V 6 Input port L for rectifier bridge CN1 3 Compressor...

Страница 18: ...Port for low pressure switch CN17 25 Port for transformer input CN40 7 Port for high pressure sensor CN3 Reserved 26 Reserved CN38 8 Port for TL temperature sensor CN7 Reserved 27 Reserved CN37 9 Port...

Страница 19: ...EVU ON If the heat pump in heating mode The heat pump automatically activates the boost function 3 SG ON EVU OFF The unit will operate normally 4 SG OFF EVU OFF The maximum running hours of the compr...

Страница 20: ...n connected properly and that the ground terminals are tightened Internal wiring Visually check the switch box for loose connections or damaged electrical components Mounting Check that the unit is pr...

Страница 21: ...leave the unit unattended when service panel is removed Refrigerant supplement Each unit has been equipped with sufficient refrigerant when leaving the factory Do not charge or change the refrigerant...

Страница 22: ...top panel 10 2 2 Titanium heat exchanger replace The titanium heat exchanger s remove and installation can only by loosening the copper tube at the top use welding torch WARNING Do not repair or repla...

Страница 23: ...20 10 2 3 Inverter drive board replace Remove the connecting wires from the inverter drive board before taking it out if necessary 1 2 3 4 5 6...

Страница 24: ...nsor T2 malfunction 17 H3 Gas refrigerant temp sensor T2B malfunction 18 H4 Three times L0 protecs 19 H6 The DC fan malfunction 20 H7 Voltage protection 21 H8 HP pressure sensor malfunction 22 HA Outl...

Страница 25: ...ks are ok the fault still exists please contact the installer or retailer 4 bA Ambient temp Out of operation range 1 Check whether the ambient temperature is lower than the operating range of the unit...

Страница 26: ...ty kW 4 50 5 20 7 00 7 80 8 60 EER 4 00 3 35 4 00 3 00 2 60 Sound pressure level 1m dB A 41 43 49 50 54 Silence mode sound pressure level 1m dB A 39 39 40 41 43 Water flow m h 3 1 3 9 5 4 6 9 8 3 Wate...

Страница 27: ...ng any hot work A degree of ventilation shall continue during the period that the work is carried out The ventilation should safely disperse any released refrigerant and preferably expel it externally...

Страница 28: ...m remote from the leak Oxygen free nitrogen OFN shall then be purged through the system both before and during the brazing process 15 Removal and evacuation When breaking into the refrigerant circuit...

Страница 29: ...mbers of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant i e special cylinders for t...