Table-2 Service menu
Level 1 Menu
Level 2 Menu
Content Settings
ROOM SENSOR
CONFIGURATION
LOCATION
WIRED CONTROLLER / INDOOR UNIT(default)
OFFSET
-5°C / -4°C/ -3°C/ -2°C/ -1°C/ 0°C(default) / 1°C/
2°C / 3°C / 4°C / 5°C
-5°F / -4°F / -3°F / -2°F / -1°F / 0°F(default) / 1°F/
2°F / 3°F / 4°F / 5°F
WIRED CONTROLLER
CONFIGURATION
ROLE
MAIN(default) / SECONDARY
MAIN(default) / SECONDARY
ENABLED/ DISABLED(default)
SETTING CONFIGURATION
Temperature increment(°C display only):
0.5 / 1(default)
Fan speeds 3 / 7 (default)
TEMP SETTING LIMITS
Cooling mode minimum: 17 ~ 30°C (62 ~ 86°F), default: 17°C(62°F)
Heating mode maximum: 17 ~ 30°C (62 ~ 86°F), default: 30°C(86°F)
INFRARED RECEIVER
Sets if the wired controller can receive the remote controller signal and
forward the signal to the IDU ENABLED (default)/ DISABLED
AUTO RESTART
ENABLED (default)/ DISABLED
CLEAN FILTER REMINDER
PERIOD
NONE(default) / 1250HOURS / 2500HOURS / 5000 HOURS /
10000HOURS