Page no. 19 | Configuration Interface
Table 12 – Image Format control parameters
Remarks:
1.
The dimension is calculated after horizontal binning, decimation or any other function changing the horizontal dimension of the image.
2.
Conversion in Frame Grabber is possible according to input camera, PixelFormat, resolution and HW capabilities.
0x00000332
BayerGB10
0x00000333
BayerGB12
0x00000341
BayerBG8
0x00000342
BayerBG10
0x00000343
BayerBG12
Scan Type
Scan type of the sensor of the
device
DeviceScanType
Enumeration
0
Areascan
only “Areascan” is
available for now
1
Linescan
Test Pattern
Selects the type of test pattern
that is generated by the device
as image source
TestPattern
Enumeration
0
Off
0x09
GrayHorizontalRamp
0x01
GrayVerticalRamp
0x49
GrayDiagonalRamp
0x0101
SensorChessboard
0x010
SensorGrayHorizonta
lRamp
0x030
SensorGrayVerticalRa
mp
Vertical invert
Flip image vertically. The ROI
will stay as original image.
ReverseY
Boolean
0
False
1
True
Horizontal
invert
Flip image horizontally. The
ROI will stay as original image.
ReverseX
Boolean
0
False
1
True