2 0 H a M e s i l a S t . , N e s h e r 3 6 8 8 5 2 0 , I s r a e l
P O B 2 5 0 0 4 , H a i f a 3 1 2 5 0 0 1 , I s r a e l
T e l : ( + 9 7 2 ) - 7 2 - 2 7 2 3 5 0 0 F a x : ( + 9 7 2 ) - 7 2 - 2 7 2 3 5 1 1
Page no. 9 | Mechanical Properties
5.6
GPIO connector
The following table describes the pin out of the Hirose 6 pin female connector:
Table 5 – GPIO connector pin out
(1) Used for external exposure indication as well as for the serial communication (cannot be used for both at the same time).
(2) Used for external trigger as well as for the serial communication (cannot be used for both at the same time).
Figure 2 – GPIO connector pin out
NOTE: An HR10A-7P-6S (Hirose Electric) connector or equivalent should be used on the cable side.
5.7
QSFP+ Installation
5.7.1
Installing the QSFP+ Module
In order to install the QSFP+ module, follow these steps:
1.
Remove the dust plugs from the module.
2.
The QSFP+ module has a pull-tab latch that used to remove or install the module.
3.
Hold the transceiver so that the identifier label is on the top.
4.
Align the QSFP+ transceiver in front of the module’s transceiver socket opening and carefully slide the
QSFP+ transceiver into the socket until the transceiver makes contact with the connector.
5.
Make sure that the male connectors on the module will align with the female connectors inside the
cage.
Pin number
Pin description
1
GND
2
RS232 TX1(1)
3
RS232 RX1(2)
4
RS232 TX2
5
RS232 RX2
6
21V (output)