ENGLISH 

CAUTION 

In order to use the face mask safely and avoid risks it is fundamental that these 
instructions  and  those  relative  to  the  filters  be  clearly  understood.  Particular 
attention is to be paid to warnings, cautions and use limitations.  
 
IMPORTANT: 
1.  Before using the face mask be sure to understand fully and adhere to all the 

instructions herein. 

2.  Use the face mask only for the purposes stated.  
3.  Use only original KASCO spare parts for the maintenance of this face mask. 
4.  Product  responsibility  for  the  correct  functioning  of  this  face  mask  is 

irrevocably transferred to the owner/end user if: 

-  The  face  mask  is  maintained  or  repaired  by  personnel  or  by service 
centres not employed or authorised by Kasco. 
- The face mask is used in a manner or for uses not conforming to its 
intended use as specified in these instructions. 

 

1. APPLICATION

 

1.1 Description

 

Full face mask with black silicone face blank and wide view polycarbonate visor, 
threaded  connection  according  to  UNI  EN  148-1:2000  standard,  two  inhalation 
valves  on  the  internal  half  mask  and  an  exhalation  valve,  5  point  harness 
attached to the visor. 
The face mask comes in three sizes: 
- size S (small), described above 
- size M (medium) with five harness attachments fixed to the sealing edge 
- size L (large), with harness as per size M 
In order to protect the respiratory system effectively, the mask is to be equipped 
with filters/cartridges manufactured by KASCO only. 

The ZENITH1 (P/N 1005009) is supplied in the following versions: 

 

1005009 - X  Y  Z 

 

 
 
 
 
 
 

 

Twelve  different  codes/part  numbers  are  obtained  from  the  combination  of  the 
different versions as follows: 

 

1005009

SME, 1005009

SMP, 1005009

SPE, 1005009

SPP; 

1005009

MME, 1005009

MMP, 1005009

MPE, 1005009

MPP; 

1005009

LME, 1005009

LMP, 1005009

LPE, 1005009

LPP. 

It is assumed that the abbreviated code/part numbers: 

 

1005009

S is equivalent to 1005009

SPP; 

1005009

M is equivalent to1005009

MPP; 

1005009

L is equivalent to1005009

LPP. 

The  full  face  mask  is  composed  of  materials  which  make  it  suitable  for  use  in 
explosive atmospheres. 
The full face mask may also be used as a component of power assisted filtering 
devices  (PAPR).  (See  relative  respirator  composition  chart  and  User 
Instructions).

 

 
1.2 Function

 

Breathable, filtered, air passes through the inhalation valves to the inside of the 
visor. 
The filtered air flows over the visor minimising visor misting then passes through 
check valves to the inner mask. 
Exhaled air is expelled through the exhalation valve. 

1.3 Reference standards

 

The  full  face  mask  is  designed  to  and  complies  with  the  requirements  of  the 
technical  standard  EN136:1998  and  meets  the  performance  requirements  laid 
down therein.

 

1.4 Use 

The  full  face  mask,  with  the  limitations  specified  at  clause  1.6,  may  be  used 
exclusively  for  respiratory  protection  against  gases  and/or  liquid  and  solid 
aerosols. See filter/cartridge instructions for permissible concentrations. 

1.5 Protection factor

 

The  full  face  mask  protection  factor  is  determined  by;  the  face  mask  seal,  the 
filter  protection  class,  the  state  of  conservation  and  maintenance  of  the  face 
mask.  

1.6 Use Limitations

 

Do not use the face mask if: 

 

the nature and concentration of the contaminant present in the atmosphere 
is not known.  

 

the  concentration  of  the  contaminant  in  the  atmosphere  exceeds  the  filter 
protection class limits (See filter use instructions).  

 

the type of contaminant is not provided for by the type of filter.  

 

the oxygen concentration in the atmosphere is lower than 17% in volume.  

 

in  closed  work  locations  (ex.  tanks, duct, silos underground locations) and 
fresh air delivery systems are not available. 

Use limitations for PAPR’s may be found in relative Use Instructions

 

1.7 Cautions

 

The full face mask is to be used only by workers: 

 

who have been trained on the use of respiratory protective devices.  

 

who do not have respiratory problems or an impaired sense of smell. 

 

who do not have sideburns, a beard and/or a moustache as these will 
hinder a good face mask seal. 

 

Who do not use eyewear. 

Do not use the face mask: 

 

if it has not been thoroughly cleaned and disinfected. 

 

if it has failed the face seal tightness test. 

 

if there is a doubt that parts are missing and/or one or more parts look 
defective. 

 

if there is no evidence of period maintenance.  

 

with oxygen cylinders or in oxygen enriched atmospheres.  

Return to fresh, clean air immediately and remove face mask in the case: 

 

of uncommon smell or taste. 

 

of unjustified or sudden irritation of the nose or throat .  

 

of inhaled air becoming extremely hot.  

 

dizziness, nausea or headaches occur. 

 
2. CLASSIFICATION

 

Full face mask for special uses : CLASS 3 

 
3. INSPECTION 

Before using the face mask make sure that:  

 

it is clean and disinfected and does not present evident defects.  

 

there are no parts missing. 

 

the inhalation and exhalation valves have been properly inserted. 

 

the filter sealing gasket is properly housed.  

 

4. DONNING AND FITTING 
4.1  Donning 

 

Don the face mask before entering the contaminated area. 

 

Release the strap buckles and pull the straps through as far as they will go.  

 

Spread out the two lateral straps. 

 

Slip carrying strap around neck and position chin in the chin support.  

 

Position face mask against the face, pass the harness over the head and 
pull straps back in the following sequence: cheek straps, temple straps, 
forehead strap.  

The ideal position of the mask against the face is obtained when, without 
excessive pulling, the mask fits snugly and the seal provides an even pressure 
distribution over the entire area in contact with the face. 

4.2 Seal Tightness test

 

After having donned the mask and obtained a good fit press the palm of your 
hand over the threaded connector and inhale slightly in order to generate 
negative pressure. Hold your breath for a second and if no air leaks are detected 
a good fit has been obtained. If air leaks are detected pull straps tighter and 
repeat test. If leakage persists reposition the face mask as described at point 4.1  
and 4.2 and repeat seal tightness test. 

4.3 Exhalation valve test

 

Cover the threaded connector with the palm of your hand and exhale. Exhaled 
air should flow out of the mask without appreciable resistance.  
 

5 USE 
5.1 Aplication: 

Some of the uses for which the protective device, equipped with proper filter, has 
been designed: 
• Asbestos reclamation and abatement: removal of untreated and dry asbestos 

coverings; asbestos handling and disposal; glass production activities, 
means of transport gaskets. 

• Chemistry and pharmaceuticals: powder formulation, chemical formulations and 

special pastes; biological risk and infectious diseases. 

• Construction, building and renovation: Concrete, cement, stone, masonry and 

plaster handling / cutting / smoothing / grinding /drilling; Surface painting 
and coating; restructuring; controlled demolition. 

• Waste management: Handling and disposal of waste; Decontamination; Waste 

removal. 

• Metal working: Machining and scraping. 
• Woodworking: cutting / planing / drilling; scraping and sanding. 

 Glass fibers and minerals processing: Mineral tile laying; Spraying operations; 

Mineral extractions and marble work. 

 

Maintenance: Disinfection and cleaning with acids, aldehydes. 

 

 

Spray painting and sandblasting: Powder coating; Spraying / latex painting; 

Wet or dry sandblasting.

 

5.2 Instructions:

 

Screw on proper filters only after the mask has been tested and has passed the 
seal tightness test. 
The use of the mask is determined by the type and model of filter used. Follow 
the  filter  Use  Instructions  packed  with  filters  and,  in  any  case,  leave  the  area 
immediately  if  smell  or  taste  of  the  contaminant  is  detected  or  if  breathing 
becomes more difficult. 
For use in extreme conditions adhere to the following cautions: 

 

In  the  case  of  extremely  low  temperatures  treat  visor  with  an  anti-misting 
liquid (compatible with the eyes and skin and which will not damage rubber 
and plastic) and regularly check the exhalation valve diaphragm as it could 
harden resulting in possible leakage.  

Code/part 
number: 
1005009

 

Size: 

= Small 

M = 

Medium 

= Large

 

Buckle type: 

= Metal 

=

 

Plastic

 

Harness: 

= EPDM 

= PVC

 

Содержание ZENITH1

Страница 1: ...TRUZIONI D USO USE INSTRUCTIONS GEBRAUCHSANLEITUNG MODE D EMPLOI INSTRUCCIONES PARA EL USO INSTRU ES DE USO ZENITH1 1005009 MASCHERA A PIENO FACCIALE FULL FACE MASK VOLLGESICHTS MASKE MASQUE COMPLET M...

Страница 2: ...iratore sono specificate nel relativo manuale di istruzioni 1 7 Avvertenze La maschera pu essere utilizzata solo da personale addestrato all uso di mezzi protettivi delle vie respiratorie senza proble...

Страница 3: ...ta funzionalit e assenza di perdite 1 3 3 Connettore maschera Controllare anello di tenuta Sostituire anello di tenuta 1 Valvole di esalazione Controllare il disco valvola Sostituire il disco valvola...

Страница 4: ...respiratory problems or an impaired sense of smell who do not have sideburns a beard and or a moustache as these will hinder a good face mask seal Who do not use eyewear Do not use the face mask if i...

Страница 5: ...r each use every 6 months once a year Full face mask Complete Cleaning Disinfecting Seal and exhalation valve test 1 3 3 Equipment connector Sealing ring inspection Sealing ring replacement 1 Exhalati...

Страница 6: ...gende Kenntnisse bzw Eigenschaften verf gt Schulung zur Verwendung von Schutzmitteln f r Atemwege Keine Probleme mit dem Atem und Geruchssystem Kein Bartwuchs der mit dem Dichtk rper interferieren w r...

Страница 7: ...etzen 1 Ausatemventil Die Ventilscheibe kontrollieren Die Ventilscheibe ersetzen 1 Einatemventil Die Ventilscheibe kontrollieren Die Ventilscheibe ersetzen 2 1 Ventile der Innenmaske kontrollieren Die...

Страница 8: ...sur d ventuelles pi ces manquantes et ou si une ou plusieurs pi ces pr sentent un d faut s il n a pas t entretenu r guli rement avec de l oxyg ne ou dans une atmosph re enrichie en oxyg ne Revenir imm...

Страница 9: ...i dessus peuvent tre effectu s avec des outils classiques Les soupapes se diff rencient par les couleurs suivantes ROUGE soupape d inspiration masque int rieur JAUNE soupape d inspiration masque NOIR...

Страница 10: ...i dico con ox geno o para atm sferas enriquecidas de ox geno Salir inmediatamente al aire libre y al aire limpio y quitarse la m scara si se sienten sabores u olores se siente una injustificada y repe...

Страница 11: ...te La sustituci n de los componentes como se indica en la tabla anterior puede ser efectuada con herramientas comunes Las v lvulas se distinguen por los siguientes colores v lvula de inspiraci n de la...

Страница 12: ...UNI EN 148 1 2000 S M L M Kasco 1005009 ZENITH1 1005009 X Y Z 12 1005009 SME 1005009 SMP 1005009 SPE 1005009 SPP 1005009 MME 1005009 MMP 1005009 MPE 1005009 MPP 1005009 LME 1005009 LMP 1005009 LPE 10...

Страница 13: ...8 IDP109 Pg 13 di 15 spray 6 6 1 50 C 7 7 1 7 2 7 3 8 8 1 o ring 60 o ring 8 2 8 1 o ring 8 3 6 1 3 3 1 1 2 1 2 1 2 3 KASCO 8 4 OR KASCO KASCO 9 ID 1 2 2016 425 3 2016 425 4 5 6 7 8 9 10 11 12 13 CE 2...

Страница 14: ...tada cuidadosamente se o resultado do teste de estanqueidade for negativo se houver d vidas de que faltam partes e ou uma ou mais pe as apresentem defeitos se n o houver a evid ncia de uma manuten o p...

Страница 15: ...ntrolar o disco da v lvula 2 1 Controlar apenas casualmente se as m scaras estiverem embaladas hermeticamente 2 Os discos das v lvulas s o produzidos em silicone prova de envelhecimento Substituir ape...

Страница 16: ...igo de art culo C digo do artigo 1004004 Descrizione articolo Item description Artikelbeschreibung Description de l article Descripci n del art culo Descri o do artigo MEMBRANA VALVOLA DI ESPIRAZIONE...

Отзывы: