background image

Kasco Model C-20 Time & Temperature Unit Control 

Owners Instructions 

(Please read completely before installing and operating your Kasco Equipment) 

CAUTION: 

To ensure the safe operation and long life of your Kasco 
Equipment, always take the following precautions: 

• 

Always

 keep people and objects clear of the De-Icer pro-

peller when operating. 

• 

Always 

disconnect

 the power before servicing or remov-

ing your De-Icer. 

• 

Always operate your Kasco De-Icer 

in the water

!  Oper-

ating your De-Icer dry (on shore or dock) can cause 
damage to the seals or injure operator. 

• 

Always

 mount your C-20 on a 

vertical surface 

and oper-

ate only with the 

cover closed

• 

Never

 lift your Kasco De-Icer or C-20 control by the 

power cable.  This could damage the power cable and 
make your De-Icer or control unsafe to operate. 

• 

Kasco Marine highly recommends that all possible 

pre-

cautions be taken

 around open water De-Icing areas to 

ensure the safety of the public, i.e., “Thin Ice” and/or 
“Open Water” signs, appropriate lighting, fencing or 
other safety measures as required in your area. 

• 

There are certain conditions under which no circulator 
can prevent ice damage such as ice that moves due to 
wind or current, extremely cold weather where ice forms 
all the way to the bottom and in some cases where the 
bottom water temperature is the same as ice (very shal-
low water).  Effective operation can be somewhat re-
stricted by too little bottom clearance. 

 

INSPECTING YOUR C-20 UNIT CONTROL: 

Upon receiving your Kasco C-20 Unit Control, please un-
pack and inspect your C-20 for any possible damage that 
may have happened during shipment.  Any damage or short-
age should be reported to your dealer/delivery service imme-
diately to ensure prompt resolution. 
 

INSTALLATION: 

This unit 

must

 be mounted on a vertical surface close 

enough to your power supply to allow at least a slight slack 
in the power cord from the C-20.  Select the screw(s) with 
which to mount your C-20.  You will need one for the slot 
near the top of the box and you may wish to utilize the two 
additional mounting holes located near the inside bottom of 
the C-20 box.  At this time, prior to final installation, you 
may wish to do some pre-programming of the timer and 
thermostat (see Programming below). 
   Install the De-Icer power cord through the hole in the 
lower left portion of the C-20 housing and plug it into the 
receptacle inside the C-20. 
   

Important

: Your C-20 is designed to operate only one 

Kasco De-Icer.  For the most accurate operation, avoid plac-
ing your C-20 in direct sunlight.  Complete programming 
the timer and thermostat now. 

PROGRAMMING: 

The advance design of Kasco’s C-20 gives you both time 
and temperature control of your De-icer.  The C-20 is wired 
in a series configuration giving you control based on both 
time and temperature.  Your Kasco De-Icer will only operate 
when both the timer and the thermostat are activated.  The 
red indicator light will 

only

 be lit when both time and tem-

perature are activated. 

You will need to program both the timer and thermostat to 
complete your programming and we will address the how’s, 
why, and recommendations for each separately below. 

 

TIMER: 

The timer is programmable in 30 minute incre-

ments, but do 

not

 program the timer in segments of less than 

a one hour period at any time. 

• 

Setting Timer: 

1.  Pull out each tripper for every half hour of ON time be     
       tween desired hour mark on dial.

 

2.  Turn dial clockwise  

one or more revolutions until  

       correct time-of-day is adjacent to the timer arrow in the   
       center of dial. 

 

THERMOSTAT: 

The thermostat has a 6

O

F differential.  

This means that the De-Icer will come 

ON

 at the tempera-

ture setting and will not go 

OFF

 until the temperature 

reaches 6

O

F above the 

ON

 setting. 

• 

Setting Thermostat: 

      Set dial to temperature at which you wish to have     
      your Kasco De-Icer begin activation. 
 

RECOMMENDATIONS: 

Use the following guide lines and hints to assist in customiz-
ing your setting for local conditions. 

• 

De-Icers set up small localized currents the longer they 
run.  Fewer and longer operation cycles will prove to be 
more effective than more frequent and shorter operation 
cycles. 

• 

Fresh water freezes at 32

O

F, salt water at 28

O

F, and 

brackish water will freeze somewhere in between de-
pending on the salinity level.  Most people find that by 
setting the thermostat a couple degrees below the freez-
ing point, they can minimize unneeded operation time 
for two reasons: 

A.  Once activated, the thermostat stays activated until the 

temperature rises the 6

O

F differential, putting the tem-

perature above the freezing point. 

 

13 

Содержание 2400D

Страница 1: ...Warranty Claim Return Policy Maintenance Recommendations De Icer Installation Instructions Specs Sizing Replacement Parts Assembly Diagram C 10 Instructions C 20 Instructions Universal Dock Mount Ins...

Страница 2: ...when operating NEVER run the unit out of water It will damage the seals and create a dangerous situation for the operator Extreme caution should be used around open water especially cold water which p...

Страница 3: ...vironments such as in marinas or other commercial applications or on demand use as may be needed Your Kasco Marine De Icer is ready for immediate use after installation The motor is of an oil filled d...

Страница 4: ...eriodically and replaced if necessary Note There are certain conditions under which no circulator can prevent ice damage such as ice that moves due to wind or current extremely cold weather where ice...

Страница 5: ...Kasco Marine will re turn units repaired under warranty at our expense via ground freight within the continental United States Other Repairs Most failed equipment can be repaired at substantially low...

Страница 6: ...t stagnant water areas and poor water quality If you do decide to store the unit during non freezing times it is not necessary to store Kasco motors upside down All internal seals are fully lubricated...

Страница 7: ...lifting or a combination of lifting expansion is your concern you may wish to keep your dock structure or boat area completely ice free Both of these concerns or objectives are very different and may...

Страница 8: ...the bow to the stern with the least resistance It is generally easier to De Ice a boat by installing the De Icer at or near the bow angled to push the De Icing flow of wa ter toward the stern It is ge...

Страница 9: ...TEP SIX OPTIONAL On installations where open water area is required or de sired to be limited controlled a curtain technique can be used to block the flow of water and restrict the open wa ter area By...

Страница 10: ...0280 SEALING PLUG 1 3 990285 SEALING WASHER 1 4 243475 ZINC ASSEMBLY 2400 3400 MODELS 1 4A 840475 ZINC ASSEMBLY 4400 MODELS 1 5 240170 2400 K PROP 2400 MODEL 1 5A 340125 3400 J PROP 3400 MODEL 1 5B 44...

Страница 11: ...ough to your power supply to allow at least a slight slack in the power cord from the C 10 Select the screw s with which to mount your C 10 You will need two for the mounting holes at the top of the b...

Страница 12: ...ase receipt is needed for limited warranty cover age Warranty is void If thermostat is damaged by unau thorized tampering or improper use KASCO SERVICE PARTS If the service parts listed below are not...

Страница 13: ...ogramming of the timer and thermostat see Programming below Install the De Icer power cord through the hole in the lower left portion of the C 20 housing and plug it into the receptacle inside the C 2...

Страница 14: ...nd operate only on temperature pull all trippers on the timer to the ON position Bypassing the thermostat to operate only on time can only be done when temperatures are below 40O F To do so set the th...

Страница 15: ...sco urges that the base be mounted as securely as possible For salt water use Kasco suggests that you use 1 stainless steel pipe STEP ONE Determine the most suitable application for your situation Ins...

Страница 16: ...e sure all bolts and nuts are now tight If more than one set of holes align use the holes closest to the de icer STEP SEVEN Place the Clam Shell Pipe Clamp onto the pipe extension Make sure the two ha...

Страница 17: ...Position the Float upside down lengthwise channels facing up and place the Base Strap so the three holes in the Base Strap align with the three threaded holes that comprise the lengthwise midline of t...

Страница 18: ...d be on the side of the U Bracket that is closer to the cord clamp Tighten the hardware using the 7 16 wrench and socket wrench until the U Bracket clamps firmly around the cage U Bracket should pull...

Страница 19: ...nd of the motor At this time use the Nylon Tie provided to connect the power cord and front Rope to prevent the cord from tangling in the prop Also if the power cord has a Quick Dis connect and Additi...

Страница 20: ...rt back up If you are noticing these symptoms the unit should be unplugged immediately because the Thermal Overload will continue to turn on and off until it burns out and damages the motor The unit s...

Страница 21: ...or by the customer You must include the power cord and cage assembly with each unit sent in for repair to be considered for warranty repair Do not ship the float and or control box with the unit for r...

Страница 22: ...gister your Kasco De Icer online at www de icer com solutions_warranty_registration htm Also fill in the information below and keep for your records Model Ex 2400D _______________________________ Seri...

Отзывы: