background image

C-10 Thermostat Unit Control 

Owners Instructions 

CAUTION: 

To ensure the safe operation and long life of your 
Kasco Equipment, always take the following precau-
tions: 

• 

Always

 keep people and objects clear of the De-

Icer propeller when operating. 

• 

Always 

disconnect

 the power before servicing or 

removing your De-Icer. 

• 

Always operate your Kasco De-Icer 

in the water

!  

Operating your De-Icer dry (on shore or dock) 
can cause damage to the seals or injure operator. 

• 

Always

 mount your C-10 on a 

vertical surface 

and operate only with the 

cover closed

• 

Never

 lift your Kasco De-Icer or C-10 control by 

the power cable.  This could damage the power 
cable and make your De-Icer or control unsafe to 
operate. 

• 

Kasco Marine highly recommends that all possi-
ble 

precautions be taken

 around open water De-

Icing areas to ensure the safety of the public, i.e., 
“Thin Ice” and/or “Open Water” signs, appropri-
ate lighting, fencing or other safety measures as 
required in your area. 

• 

There are certain conditions under which no cir-
culator can prevent ice damage such as ice that 
moves due to wind or current, extremely cold 
weather where ice forms all the way to the bottom 
and in some cases where the bottom water tem-
perature is the same as ice (very shallow water).  
Effective operation can be somewhat restricted by 
too little bottom clearance. 

 

INSPECTING YOUR C-10 UNIT CONTROL: 

Upon receiving your Kasco C-10 Unit Control, please 
unpack and inspect your C-10 for any possible dam-
age that may have happened during shipment.  Any 
damage or shortage should be reported to your dealer/
delivery service immediately to ensure prompt reso-
lution. 

 

INSTALLATION: 

This unit 

must

 be mounted on a vertical surface close 

enough to your power supply to allow at least a slight 
slack in the power cord from the C-10.  Select the 
screw(s) with which to mount your C-10.  You will 
need two for the mounting holes at the top of the box 
and one for the mounting hole located at bottom of 
the C-10 box.   

Important

Your C-10 is designed to operate only 

one Kasco De-Icer.  For the most accurate operation, 
avoid placing your C-10 in direct sunlight.   
 
 

OPERATION: 
Step One: 

Plug the C-10 Power Cord into a properly grounded 
120V outlet. 
 

Step Two: 

Set the temperature you desire the De-Icer to turn on 
using the Thermostat dial on the C-10.  It is recom-
mended to set the temperature at 30

O

F (top black 

numbers).  The C-10 works on temperature fall.  
When the ambient air temperature reaches the set 
point on the thermostat, the De-Icer will turn on.  
There is a 2.5

O

F differential, so when the temperature 

rises to 2.5

O

F above the set thermostat temperature, 

the De-Icer will turn off. 
 

Step Three: 

Plug the 

INSTALLED 

Kasco De-Icer into the piggy-

back plug of the C-10. 
 
 

RECOMMENDATIONS & INFO: 

Use the following guide lines and hints to assist in 
customizing your setting for local conditions. 

• 

De-Icers set up small localized currents the longer 
they run.  Fewer and longer operation cycles will 
prove to be more effective than more frequent and 
shorter operation cycles. 

• 

Fresh water freezes at 32

O

F, salt water at 28

O

F, 

and brackish water will freeze somewhere in be-
tween depending on the salinity level. 

• 

Once activated, the thermostat stays activated un-
til the temperature rises the 2.5

O

F differential, 

putting the temperature above the freezing point. 

• 

If the temperature is hovering near the freezing 
point, any ice formation is minimized. 

• 

Daily observation is suggested for all de-icing 
installation

• 

A number of factors can increase freeze rates 
such as wind, snow, and colder temperatures.  A 
sunny day can actually 

retard

 freezing.   

11 

Содержание 2400D

Страница 1: ...Warranty Claim Return Policy Maintenance Recommendations De Icer Installation Instructions Specs Sizing Replacement Parts Assembly Diagram C 10 Instructions C 20 Instructions Universal Dock Mount Ins...

Страница 2: ...when operating NEVER run the unit out of water It will damage the seals and create a dangerous situation for the operator Extreme caution should be used around open water especially cold water which p...

Страница 3: ...vironments such as in marinas or other commercial applications or on demand use as may be needed Your Kasco Marine De Icer is ready for immediate use after installation The motor is of an oil filled d...

Страница 4: ...eriodically and replaced if necessary Note There are certain conditions under which no circulator can prevent ice damage such as ice that moves due to wind or current extremely cold weather where ice...

Страница 5: ...Kasco Marine will re turn units repaired under warranty at our expense via ground freight within the continental United States Other Repairs Most failed equipment can be repaired at substantially low...

Страница 6: ...t stagnant water areas and poor water quality If you do decide to store the unit during non freezing times it is not necessary to store Kasco motors upside down All internal seals are fully lubricated...

Страница 7: ...lifting or a combination of lifting expansion is your concern you may wish to keep your dock structure or boat area completely ice free Both of these concerns or objectives are very different and may...

Страница 8: ...the bow to the stern with the least resistance It is generally easier to De Ice a boat by installing the De Icer at or near the bow angled to push the De Icing flow of wa ter toward the stern It is ge...

Страница 9: ...TEP SIX OPTIONAL On installations where open water area is required or de sired to be limited controlled a curtain technique can be used to block the flow of water and restrict the open wa ter area By...

Страница 10: ...0280 SEALING PLUG 1 3 990285 SEALING WASHER 1 4 243475 ZINC ASSEMBLY 2400 3400 MODELS 1 4A 840475 ZINC ASSEMBLY 4400 MODELS 1 5 240170 2400 K PROP 2400 MODEL 1 5A 340125 3400 J PROP 3400 MODEL 1 5B 44...

Страница 11: ...ough to your power supply to allow at least a slight slack in the power cord from the C 10 Select the screw s with which to mount your C 10 You will need two for the mounting holes at the top of the b...

Страница 12: ...ase receipt is needed for limited warranty cover age Warranty is void If thermostat is damaged by unau thorized tampering or improper use KASCO SERVICE PARTS If the service parts listed below are not...

Страница 13: ...ogramming of the timer and thermostat see Programming below Install the De Icer power cord through the hole in the lower left portion of the C 20 housing and plug it into the receptacle inside the C 2...

Страница 14: ...nd operate only on temperature pull all trippers on the timer to the ON position Bypassing the thermostat to operate only on time can only be done when temperatures are below 40O F To do so set the th...

Страница 15: ...sco urges that the base be mounted as securely as possible For salt water use Kasco suggests that you use 1 stainless steel pipe STEP ONE Determine the most suitable application for your situation Ins...

Страница 16: ...e sure all bolts and nuts are now tight If more than one set of holes align use the holes closest to the de icer STEP SEVEN Place the Clam Shell Pipe Clamp onto the pipe extension Make sure the two ha...

Страница 17: ...Position the Float upside down lengthwise channels facing up and place the Base Strap so the three holes in the Base Strap align with the three threaded holes that comprise the lengthwise midline of t...

Страница 18: ...d be on the side of the U Bracket that is closer to the cord clamp Tighten the hardware using the 7 16 wrench and socket wrench until the U Bracket clamps firmly around the cage U Bracket should pull...

Страница 19: ...nd of the motor At this time use the Nylon Tie provided to connect the power cord and front Rope to prevent the cord from tangling in the prop Also if the power cord has a Quick Dis connect and Additi...

Страница 20: ...rt back up If you are noticing these symptoms the unit should be unplugged immediately because the Thermal Overload will continue to turn on and off until it burns out and damages the motor The unit s...

Страница 21: ...or by the customer You must include the power cord and cage assembly with each unit sent in for repair to be considered for warranty repair Do not ship the float and or control box with the unit for r...

Страница 22: ...gister your Kasco De Icer online at www de icer com solutions_warranty_registration htm Also fill in the information below and keep for your records Model Ex 2400D _______________________________ Seri...

Отзывы: