DS200 Installation Guide
DS200 Installation Guide
DS200 Installation Guide
DS200 Installation Guide
V003. 25.06.2002
B-20
1. Ground contact spring
4. Line status LED
7. CBL-8 line cable
2. Line connection connector (RJ45)
5. Card status LED
8. CBL-16 line cable
3. EX200B connection connector
6. Cable tie
Figure – 12
While attaching the line connection card to the expansion card, be careful about fully
inserting the connection connectors and fully fitting the line connection card into the clicks
on sides of the plastic cover. Cards that are not completely fitted cause friction with the
cards nearby, as well as they cause the LEDs on the front face not to be seen from outside,
for they would not fit.
The connectors on the line connection cards have been included only to provide for easy
replacement of the card without detaching the cabling, in case protection circuitry on the
card is damaged. While replacing the card, do not detach the cables from that connector. In
order to achieve this, during the first connection, insert the expansion module to its
corresponding place by sliding it in the slot while the cable is still loosely hanging, however,
leave it 6-7 cm before the point it is completely fixed. Then, fix the line connection cable to
the back surface of the exchange while the expansion module is in this position.