English
7
Please read and comply with
these instructions prior to the
initial operation of your appliance. Retain
these operating instructions for future refer-
ence or for subsequent possessors.
– Before first start-up it is definitely neces-
sary to read the operating instructions
and safety indications Nr. 5.951-949!
– In case of transport damage inform ven-
dor immediately
Symbols in the operating instructions
Danger
indicates an immediate threat of danger.
Failure to observe the instruction may result
in death or serious injuries.
몇
Warning
indicates a possibly dangerous situation.
Failure to observe the instruction may result
in light injuries or damage to property.
Note
indicates useful tips and important informa-
tion.
– The interior cleaner HKF 50 M is a spray
unit to clean DIN standard containers as
well as other containers and drums.
– The cleaning head is inserted into the
container through an opening with a
suitable minimum inner diameter.
– A separate high pressure pump is con-
nected to the interior cleaner via a high
pressure hose.
Operation outside closed containers and
with higher pressure and temperatures than
those listed in the "Specifications" is prohib-
ited.
– The interior cleaner consists of a drive
unit, a support pipe and the cleaning
head. The nozzles on the cleaning head
turn around two axles and therefore
touch every place in the container.
– The cleaning head is turned by an elec-
tric motor. The speed is therefore con-
stant and independent of the pressure
and the volume of cleaning liquid.
– The support pipe includes an adjustable
screw connection for the installation on
containers with threaded borings "R2"
or M64x4. As an alternative to the screw
connection, you can attach a hole cone
(see accessories).
– A double handle can be supplied to fa-
cilitate the transport (see accessories).
– Please follow the national rules and reg-
ulations of the respective country.
– Please follow the safety instructions
which are attached to the used deter-
gents (normally on the packing label).
– In order to avoid improper operation, the
system may only be used by persons
who have been instructed in handling
the system or have proven qualification
and expertise in operating the system or
have been explicitly assigned the task
of handling the system.
– The operating instructions must be ac-
cessible for every user.
Wrong operation or misuse are hazardous
to the operator and other persons on ac-
count of:
– high pressure
– high electrical voltage
– Cleaning agents or used cleaning liquid
Danger
–
Danger of crushing by the interior clean-
er. Only use the interior cleaner's drive
in closed containers.
–
Danger of injury by high pressure jet -
therefore only use interior cleaner inside
closed containers.
–
Health hazards posed by residue in
containers that are cleaned or by the
cleaning liquid used. Therefore, the list-
ed protective measures must be ad-
hered to.
–
Risk of injury due to interior cleaner top-
pling over at low submerge depth. In
this case, the interior cleaner must be
supported.
–
Risk of injury by toppling container -
therefore use extra support for contain-
er and interior cleaner.
몇
Warning
In order to avoid damage to the cleaning
head, ensure a free layout inside the con-
tainer. The cleaning head must never touch
the container wall.
Approved operators are persons who are at
least 18 years old and are able to operate
this system (exceptions: apprentices, see
BGV D15 §6).
Î
Switch off the separate high pressure
pump.
Î
Pull out the mains plug.
Î
Shut off the cleaning liquid supply.
Contents
Environmental protection
The packaging material can be
recycled. Please do not throw
the packaging material into
household waste; please send
it for recycling.
Old appliances contain valua-
ble materials that can be recy-
cled; these should be sent for
recycling.. Batteries, oil, and
similar substances must not
enter the environment. Please
dispose of your old appliances
using appropriate collection
systems.
Symbols in the operating in-
structions
Proper use
Cleaning head
Minimum contain-
er opening
HKF 50 M
50 mm
Please do not let mineral oil contaminat-
ed waste water reach soil, water or the
sewage system.
Function
Safety instructions
Approved operators
Behaviour in emergency situations
Technical specifications
HKF 50 M
Order No.
3.631-039
Max. flow rate
l/h (l/
min)
1200 (20)
Max. temperature of
the cleaning liquid
°C
85
Max. operating
pressure
MPa
(bar)
15 (150)
Voltage
V
230
Current type
--
1~
Frequency
Hz
50
Rated power
W
40
Type of protection
--
IP 55
Functional speed -
drive
1/min
11
High pressure con-
nection
--
M22x1,5
Minimum container
opening
mm
50
Total length
mm
1265
Max. immersion
depth
mm
850
Weight kg
7,8
Ambient tempera-
ture
°C
+2...+40
Содержание HKF 50 M
Страница 2: ...2...
Страница 47: ...47 5 951 949 47 47 47 47 47 48 48 48 49 49 49 50 CE 50 50 HKF 50 M DIN R2 M64x4 18 BGV D15 6 HKF 50 M 50 mm...
Страница 49: ...49 30 K rcher Kaercher 1 2 3 4 A B 5 901 068...
Страница 55: ...cc 55 5 951 949 55 55 55 55 55 56 56 57 57 57 57 58 58 58 HKF 50 DIN R2 M64x4 18 BGV D15 6 HKF 50 M 50...
Страница 57: ...cc 57 1 K rcher K rcher 1 2 3 4 A B...
Страница 91: ...91 5 951 949 91 91 91 91 91 92 92 92 93 93 93 94 94 94 HKF 50 M DIN R2 M64x4 18 BGV D15 6 HKF 50 M 50...
Страница 93: ...93 K rcher Karcher 1 2 3 4 A B 5 901 068...
Страница 107: ...107 5 951 949 107 107 107 107 107 108 108 108 109 109 109 110 CE110 110 HKF 50 D N R2 M64x4 18 BGV D15 6 HKF 50 M 50...
Страница 109: ...109 K rcher K rcher 1 2 3 4 A B 5 901 068...